Epever Tracer2606EPLI Handbuch - Seite 2
Blättern Sie online oder laden Sie pdf Handbuch für Inverter Epever Tracer2606EPLI herunter. Epever Tracer2606EPLI 6 Seiten. Mppt solar charge controller with built in led driver
BEIJING EPSOLAR TECHNOLOGY CO., LTD.
4) Real-time Control
Control the load ON/OFF time through setting real-time clock.
NOTE: In the mode of Light ON/OFF and Light ON/Timer, the Load is
turned on after 10Min. delay.
8. Protection
PV Reverse Polarity
Fully protection against PV reverse polarity, correct the wire connection to resume
normal operation.
WARNING: Controller will be damaged when the PV array straight
polarity and the actual operation power of the PV array is 1.5 times
greater than the rated charge power!
Battery Reverse Polarity
Fully protection against battery reverse polarity, correct the wire connection to
resume normal operation.
Battery Over Voltage
When the battery voltage reaches to the set point of Over Voltage Disconnect Voltage,
the controller will stop charging the battery to protect the battery from being over
charged to break down.
Battery Over Discharge
When the battery voltage reaches to the set point of Low Voltage Disconnect Voltage,
the controller will stop discharging the battery to protect the battery from being over
discharged to break down.
Battery Overheating
The controller detects the environment temperature through the external temperature
sensor. If the environment temperature exceeds 65 º C, the controller will
automatically start the overheating protection to stop working, and recover below 55
º C.
Load Short Circuit
Load will be switched off when load short circuit (≥4 times rated current) happens.
Controller will automatically attempt to reconnect load for 5 times. If short circuit
protection still exist after controller's 5 times attempts, user have to clear short
circuit ,then restart the controller or wait for one night-day cycle (night time>3 hours).
Temperature sensor break down
If the temperature sensor short-circuited or damaged, the controller will be charging
or discharging at the default temperature 25 º C to prevent the battery damaged from
overcharging or over discharged.
High Voltage Transients
The controller is protected against small high voltage transients. In lightning prone
areas, additional external suppression is recommended.
9. Troubleshooting
Faults
Possible reasons
LED Charging indicator
turn off during daytime
PV
when sunshine falls on
array disconnection
PV modules properly
Battery voltage maybe
No LED indicator
less than 9V
Battery LED indicator
Battery over voltage
green fast Flashing
10. Technical Specifications
Item
Models
Nominal system voltage
Battery input voltage range
Rated charge current
Rated charge power
①
Max. PV open circuit voltage
MPP Voltage range
Max. output current
Max. output power
Output voltage range
Load open circuit voltage
Maximum output efficiency
Output current control accuracy
Battery Type
Equalize Charging Voltage
※
※
Boost Charging Voltage
Float Charging Voltage
※
Low Voltage Reconnect Voltage
※
Low Voltage Disconnect Voltage
※
Self-consumption
Temperature compensation
coefficient
Communication
Working environment
temperature
Enclosure
Overall dimension
Mounting hole size
Mounting dimension
Power cable
Net weight
※
Above parameters are in 12V system at 25 º C, please double the values in 24V system.
Troubleshooting
Confirm
that
battery wire connections
are correct and tight
Measure battery voltage
with the multi-meter.
Min.9V can start up the
controller
Check if battery voltage is
higher than OVD, and
Tracer1305EPLI
Tracer2606EPLI
12VDC
9~16VDC
10A/12V
10A
130W/12V
130W/12V
260W/24V
48V (Min. Temp.)
58V at minimum operating environment temperature
46V at 25℃ environment temperature
45V(25℃)
( Battery voltage+2V)~36V
3.3A
3.3A
100W
100W
( Max. battery
( Max. battery voltage+2V)~58V
voltage+2V)~46V
46V
124×89×30mm
88×76mm
PV/BAT:14AWG(2.5mm
LOAD:18AWG(1.0mm
0.51kg
0.52kg
3
Tel:+86-10-82894112 / 82894962 Website:www.epsolarpv.com/www.epever.com
Battery LED indicator
red
Battery LED indicator
red flashing
Charging(green) and
battery indicator
(orange)flashing
simultaneously
Powering on normally,
the load is off
The dimming function is
invalid
Parameter settings fail
①When the battery is over discharged, the battery indicator will be red and the load will be off all the
time before the voltage is more than the Low Voltage Reconnect Voltage (LVRV). In order to judge the
system is normal or not, firstly measuring the battery voltage whether is more than LVRV, if not,
restarting the controller to detect the load whether it is normal.
Note: The LVRV can be set, but it must pay more attention that it maybe damages the battery if
the LVRV is too low.
11. Disclaimer
This warranty does not apply under the following conditions:
Damage from improper use or use in an unsuitable environment.
PV
and
PV or load current, voltage or power exceeding the rated value of controller.
The controller is working temperature exceed the limit working environment
temperature.
User disassembly or attempted repair the controller without permission.
The controller is damaged due to natural elements such as lighting.
The controller is damaged during transportation and shipment.
Tracer3906EPLI
Tracer5206EPLI
15A
20A
195W/12V
260W/12V
390W/24V
520W/24V
4.5A
6.6A
130W
200W
58V
96%
≤2%
Sealed(Default) / Gel / Flooded /User
Sealed:14.6V / Gel:— / Flooded:14.8V / User:9~17V
Sealed:14.4V / Gel:14.2V / Flooded:14.6V / User:9~17V
Sealed / Gel / Flooded:13.8V / User:9~17V
Sealed / Gel / Flooded:12.6V / User:9~17V
Sealed / Gel / Flooded:11.1V / User:9~17V
≤15mA/12V;≤22mA/24V
-3mV/℃/2V
IR communication
-40℃~+60℃
IP68(1.5m,72h)
150×93.5×32.7mm
153×105×52.1mm
Φ3.5mm
120×83mm
120×94mm
2
)
PV/BAT:12AWG(4mm
2
)
LOAD:16AWG(1.5mm
0.75kg
1.19kg
Battery
①
over discharged
Battery Overheating
System voltage error
①The connecting wires
are error or
virtually connected
②Load mode is not
appropriate.
③This controller does not
match with the LED light.
④Output short circuit.
The controller does not
match with the LED light
source. This product is a
step-up voltage control, If
input voltage is lower than
the rated voltage, it is not
working.
Infrared communication
error
Any changes without prior notice! Version number:V3.1
Tracer2610EPLI
Tracer3910EPLI
12/24VDC Auto
9~32VDC
10A
15A
130W/12V
195W/12V
260W/24V
390W/24V
95V at minimum operating environment temperature
92V at 25℃ environment temperature
( Battery voltage+2V)~72V
3.3A
4.5A
100W
130W
( Max. battery voltage+2V)~80V
124×89×30mm
150×93.5×32.7mm
88×76mm
120×83mm
2
)
PV/BAT:14AWG(2.5mm
2
)
LOAD:18AWG(1.0mm
0.52kg
0.75kg
4
disconnect the PV
When the battery voltage
is restored to or above
LVR point (low voltage
reconnect voltage), the
load will recover
The controller will
automatically turn the
system off. But while the
temperature decline to be
below 50 º C, the controller
will resume.
Check whether the battery
voltage match with the
controller's working
voltage, If not please
change to a suitable
battery or reset the
working voltage
① Check the connecting
cable.
② Check the load's mode
and parameters.
③The voltage of LED light
is not within the output
voltage range of controller.
④Check the connecting
cables and LED light.
①Replace the LED light.
②Reduce system rated
voltage grade and replace
the product model.
For example 24V system
change to 12V system,
and replace the
corresponding controller
Refer to handheld the user
device manual
Tracer5210EPLI
20A
260W/12V
520W/24V
6.6A
200W
80V
153×105×52.1mm
120×94mm
2
2
)
PV/BAT:12AWG(4mm
)
2
2
)
LOAD:16AWG(1.5mm
)
1.18kg