EPH Controls R17-RF Betriebsanleitung - Seite 2

Blättern Sie online oder laden Sie pdf Betriebsanleitung für Schalter EPH Controls R17-RF herunter. EPH Controls R17-RF 2 Seiten. 1 zone rf timeswitch

R17-RF - 1 Zone RF Timeswitch
10. Holiday mode
Lower the cover on the front of the unit.
Move the selector switch to the RUN position.
Press the
button.
Holiday
The current date and time will ash on the screen. It is now
possible to enter the date and the time when you plan to return.
Press the
or
buttons to select the day.
Press the
or
buttons to select the month.
Press the
or
buttons to select the year.
Press the
or
buttons to select the hour.
To activate Holiday mode press the
To cancel Holiday mode press the
Otherwise Holiday mode will deactivate on the time and date entered.
11. Connect the RF thermostat with the timeswitch
On the timeswitch
Lower the front cover and move the selector switch to
the RUN position. Press the
Wireless Connect will appear on the screen.
On the RFR wireless room thermostat or RFC wireless cylinder thermostat
Press the Code button. This is located inside the housing on the PCB.
On the timeswitch
Zone 1 will begin to ash. Press the
The wireless symbol
appears on the screen.
The thermostat will count upwards to the number of the zone that it is paired
with. When it reaches the number of the zone that it is paired with press the
wheel on the thermostat.
The timeswitch is now operating in the wireless mode. The temperature of the
wireless thermostat is now displayed on the timeswitch.
12. Disconnect the RF thermostat from the timeswitch
On the timeswitch
Lower the front cover and move the selector switch to
the RUN position.
Press the
button for 5 seconds.
Wireless Connect will appear on the screen.
Press the
button for 3 seconds. This will clear all RF connections
thereby disconnecting all thermostats from the timeswitch.
Press the
button.
13. Backlight mode selection
There are two settings for selection. The factory default setting is ON.
ON
The backlight is permanently ON.
AUTO
On pressing any button the backlight stays on for 10 seconds.
To adjust the backlight setting
Lower the cover on the front of the unit.
Move the selector switch to the RUN position.
Press the
button for 5 seconds.
Press either the
or
Press the
button.
RUN
CLOCK
SET
Press
Holiday
Press
Holiday
Press
Holiday
Press
Holiday
button.
button again.
CLOCK
SET
button for 5 seconds.
button on the timeswitch.
CLOCK
SET
On
CLOCK
SET
buttons to select the ON or AUTO mode.
EPH Controls Ireland
Sitecast Industrial Estate, Pouladu ,
Cork, T12 W665, Ireland
[email protected] www.ephcontrols.com
14. Keypad lock and unlock
PROG
To lock the keypad, press and hold the
SET
5 seconds.
To unlock the keypad, press and hold the
5 seconds.
unlocked.
15. Copy function
Copy function may only be used if the timeswitch is in the 7d mode.
Lower the cover on the front of the timeswitch.
Move the selector switch to the PROG SET position.
First, program one of the days of the week with a schedule you wish to
copy to other days.
While still on that day press and hold the
This will take you into the Copy screen.
RUN
The day of the week that is to be copied is shown and the day it is to be
PROG
copied to is ashing.
SET
Press the
Press the
Continue by pressing the
ashing and by pressing the
When you are nished press the
return to the standard schedule programming screen.
Move the selector switch to the RUN position.
16. Frost protection function
Selectable range 5~20°C. This function is set to protect pipes against
freezing or to prevent low room temperature when the timeswitch is
programmed to be OFF or is manually OFF.
Frost protection can be activated by following the procedure below.
RUN
Move the selector switch to the RUN position.
PROG
SET
Press both the
Press either the
protection.
Press
button to con rm.
Press either the
frost protection setpoint. Press
Zone 1 will be switched ON in the event of room temperature falling below
the frost protection setpoint.
17. Master reset
Lower the cover on the front of the timeswitch. There are four hinges
holding the cover in place. Between the 3rd and 4th hinges there is a
circular hole. Insert a ball point pen or similar object to master reset the
timeswitch.
RUN
After pressing the master reset button, the date and time will now need
PROG
to be reprogrammed.
SET
EPH Controls UK
Unit E4, Welland Business Park, Valley Way, Market Harborough,
Leicestershire, LE16 7PS, United Kingdom
[email protected] www.ephcontrols.co.uk
Page 2 of 2
Operating Instructions
and
will appear on the screen. The keypad is now locked.
and
will disappear from the screen. The keypad is now
COPY
Holiday
button to copy the schedule to this day.
button to skip this day
button to copy the schedule to the day
button to skip that day.
button and the timeswitch will
and
buttons for 5 seconds, to enter selection mode.
buttons to to turn On or turn O frost
or
or
buttons to increase or decrease the desired
to select.
Unlocked
buttons for
Holiday
buttons for
Holiday
RUN
CLOCK
PROG
SET
SET
button for 3 seconds.
O