Pulse Mode:
Unlock the transportation lock and press the horizontal and/or vertical
laser line buttons. Press the pulse mode button to turn on the pulse
mode, the pulse mode LED will turn on and the laser beam line will
dim. The laser line can now be located by a detector (not included).
Press the pulse mode button again to switch off the pulse mode, the
pulse mode LED will turn off. The laser line now can not be located
with a detector.
Manual Mode:
Press the manual mode button with the transportation lock knob in
the "Lock/Off" position. The manual mode LED will flash and the
bubble light will go on. The output of the laser lines are the same as
in the self-leveling mode. Press the manual mode button again to
turn the instrument power off.
Note: When manual mode is on, the laser does not self-level and
no out-of-level alarm is indicated.