● 2 GHz processor (recommended: 2 GHz Dual Core Processor)
● 2 GB RAM (recommended: 4 GB RAM)
● Microsoft® .NET Framework 4.6 or later
Note: for the use of the calibration software and the relating
notes , please refer to CalMAN for Ruige PCC use
instruction
Program software upgrade
MCU and FPGA program upgrade
Step1.copy the MCU and FPGA upgrade program to the root
directory under DISC U
Step2.connect the U disc with the BA-100 "
OTG cable
Step3.Keep pressing the SMPTE key , power the BA-100, once
the SMPTE green light ash , release the SMPTE key , after
nishing the upgrade , ashing status disappear , if the light
ashing is always on , meaning MCU .FPGA upgrade failed
File name:Mcu***.bna,Fpga***.bnb
Such as:McuUpdateForLutLoader_150727.bna
BA-100 Technique Specication
1、SDI input distance , the testing of the breakdown point
(real testing data)
Model/Distance
Belden 1694A
Other cable transmission , refer to the below standard
Criterion
Video format
Baud rate
Model/Unit
L-2.5CFB
L-2.5CHD
L-3CFB
L-4CFB
FpgaUpdateForLutLoader_150727.bnb
SD-SDI
400M
SMPTE 344M
SD-SDI
540Mb/s
M
139
168
179
216
" based on the
HD-SDI
160M
SMPTE 292M
HD-SDI
1.5Gb/s
M
54
66
68
82
3G-SDI
120M
SMPTE 424M
3G-SDI
3.0Gb/s
M
36
46
46
55