1
Introduction
1.1 Purpose
On occasion it is necessary to convert a fully integrated front dispensing (through safe door) ArcaCash 2600
to a rear dispense (through rear safe wall) configuration. This procedure defines step-by-step the process for
performing that conversion and is based on converting a 425-580-6605 Arca2600 (UL 291 Level 1 F/A) into a
425-580-6625 Arca2600 (UL 291 Level 1 R/A).
1.2 Scope
This procedure can be performed at the factory by the manufacturer or qualified service technician on
customer site.
1.3 Tools and Materials Required
#2 Phillips Screwdriver
Small pair of Diagonal-Cutting Pliers
Cable ties
1.4 Safety
WARNING: Toggle On/Off power switch to Off position and disconnect AC power source prior to
starting this procedure.
WARNING: A second person must be available during this procedure. The dispenser must be lifted
off the tray onto the floor and later lifted back onto the tray. The 6-high dispenser weighs
approximately 90 lbs and tall narrow shape makes handling awkward.
WARNING: Do not attempt to move the 6-high dispenser while the right side cover is removed during
the dispenser conversion procedure. The 4
mated together on the right side and damage to the dispenser is likely.
2
Conversion Procedure
2.1 Remove and Reassemble the Cosmetic Door to Back Side of Safe
1. Unlatch cosmetic door and open.
2. Disconnect cable passing between the safe and the dispense indicator lights mounted to the cosmetic
door, by unplugging the black 4-position Molex-style connector.
3. Lift the cosmetic door off the hinges and set aside. Note: (2) hinge pins and (2) washers may drop off
when door is removed. Retain pins and washers for reuse later.
4. Remove (4) black plastic caps covering cosmetic door hinge mounting screws on front right side wall of
safe. Retain screw caps for reuse later.
5. Disassemble lower hinge blocks from safe by removing (4) hinge mounting screws. Retain screws for
reuse later. Note: Leave upper hinge blocks mounted to cosmetic door.