Arcam ALPHA 8R Service-Handbuch - Seite 2

Blättern Sie online oder laden Sie pdf Service-Handbuch für Verstärken Arcam ALPHA 8R herunter. Arcam ALPHA 8R 16 Seiten.

Arcam ALPHA 8R Service-Handbuch
ALPHA ONE/7R/8R/8P AMPLIFIER SERVICE MANUAL
H
/
amps or between 2.3 and 2.8mV for the Alpha 8R/8P
amps.
Leave the unit for 1 minute and reset to these values
if required.
Leave the unit for a further 5 minutes and reset if
required.
The IQ is now set and the unit can be connected to
speakers and fully checked out.
Test Point
1
2
3
4
5
6
7
8
9
10
11
12
13
Between 14 & 15
16 (protection off)
16 (protection on)
17
18
19
P
P
S

TEST POINT VOLTAGES

DC Voltage Alpha One
32.8V
27.8V
15V
-32.8V
27.8V
-15V
N/A
N/A
0.3V
3.4V
32.8V
-3V
32.8V
3.0 -3.5mV
E MAN
Disassembly For Servicing
1.
Remove the top cover and front panel.
2.
Remove 2 screws securing the sub front to the
chassis sides and 3 screws holding the
subfront to the chassis base.
3.
Remove 1 screw
chassis. This can be found near to the mains
inlet socket.
4.
Remove 5 screws from the rear panel, one at
each end and 3 along the bottom edge.
5.
Remove the transformer bolt.
6.
Release the PCB pillar located near to the
serial number on the pcb.
The pcb,
with the rear panel, transformer and
subfront attached, can now be pulled backwards out
of the unit.
DC Voltage Alpha 7R
35V
29V
15V
-35V
-29V
-15V
0.09V
0.10V
0.27V
3.2V
35V
-2.7V
-35V
3.0-3.5mV
0.0V
0.6V
0.0V
0.0V
0.0V
2
holding the pcb to the
DC Voltage Alpha 8R/8P
37V
31V
15V
-37V
-31V
-15V
0.09V
0.10V
0.27V
2.9V
37V
-2.5V
-37V
2.3-2.8mV
0.0V
0.6V
0.0V
0.0V
0.0V