RS232 commands
Status
Query the current state of Solo Movie.
Example
Command/response sequence to determine the current state (the unit is currently in stand-
by):
0x21 0x01 0x00 0x01 0xF0 0x0D
Command:
0x21 0x01 0x00 0x01 0x01 0x00 0x0D
Response:
Source selection
Change the source of Solo Movie.
Example
Command/response sequence to change the source to 'Tape':
0x21 0x01 0x01 0x01 0x03 0x0D
Command:
0x21 0x01 0x01 0x01 0x01 0x03 0x0D
Response:
Main volume
Change the volume level of Solo Movie.
Example
Command/response sequence to change Zone 1 volume to 36:
0x21 0x01 0x02 0x01 0x24 0x0D
Command:
0x21 0x01 0x02 0x01 0x01 0x24 0x0D
Response:
Balance
Change the speaker balance.
Example
Command/response sequence to set the output of the left channel, where the new balance is
3dB to the left:
0x21 0x01 0x04 0x01 0x61 0x0D
Command:
0x21 0x01 0x04 0x01 0x01 0x61 0x0D
Response:
Bass
Change the bass level.
Example
Command/response sequence to set the bass, where the new level is +1dB:
0x21 0x01 0x05 0x01 0x65 0x0D
Command:
0x21 0x01 0x05 0x01 0x01 0x65 0x0D
Response:
Arcam (A&R Cambridge Ltd), Pembroke Avenue, Waterbeach, CAMBRIDGE, CB25 9QR, England
+44 (0)1223 203200 www.arcam.co.uk/extranet
Byte:
Description:
ZN
0x01 (Zone)
CC
0x00 (Command code)
NB
0x01 (Number of bytes)
DATA
0xF0 = Query
RESPONSE
Byte:
Description:
ZN
0x01 (Zone)
RC
0x00 (Reply Code)
AC
0x01 (Answer code)
NB
0x01 (Number of bytes)
DATA
0x00 = Stand-by state
0x01 = Power-on
0x02 = Alarm
0x03 = Basic menu
0x04 = Setup menu
0x05 = Clock menu
0x06 = Initialising
0x08 = Engineering menu
0x0A = iPod menu
Byte:
Description:
ZN
0x01 (Zone)
CC
0x01 (Command code)
NB
0x01 (Number of bytes)
DATA
0x00 = DVD
0x01 = FM
0x02 = DAB/AM
0x03 = AV
0x04 = SAT
0x05 = AUX
0x06 = TAPE
0xF0 = Query
Byte:
Description:
ZN
0x01 (Zone 1)
0X02 (Zone 2)
CC
0x02 (Command code)
NB
0x01 (Number of bytes)
DATA
0x00 = Volume 0
...
0x48 = Volume 72
0xF0 = Query
Byte:
Description:
ZN
0x01 (Zone)
CC
0x04 (Command code)
NB
0x01 (Number of bytes)
DATA
0x5A = Left +10
...
0x64 = Left/Right
...
0x6E = Right +10
0xF0 = Query
Byte:
Description:
ZN
0x01 (Zone)
CC
0x05 (Command code)
NB
0x01 (Number of bytes)
DATA
0x5D = -7
...
0x64 = 0
...
0x6B = +7
0xF0 = Query