70-km Gigabit Ethernet GBIC Transceiver Installation Guide
Meaning
Corrective action
Meaning
Corrective action
Meaning
Corrective action
The event log may show one of the following informational messages:
Unqualified GBIC: I2C read error
The transceiver, which connects to the module host board through a
20-pin connector is not seated properly, and a clean connection
cannot be established.
To correct this problem, completely remove the transceiver and then
reinsert it. If the problem persists, contact 3Com Technical Support.
For contact information in the United States and Canada, call
1-800-NET-3COM. For the number to call in other locations, visit the
3Com Web site:
http://www.3com.com/util/enterprise.html
Unqualified GBIC: Checksum match error
The system uses checksum error detection to verify the integrity of the
GBIC data. If the system detects a problem with the data, it displays
an error message that indicates a checksum failure.
Although this condition does not necessarily indicate that the GBIC
transceiver will not function in the system, replace the transceiver to
ensure proper operation.
Unqualified GBIC: MODDEF Value – xx
Unqualified GBIC: Transceiver byte(s) error
For both of these messages, the value (
Module Definition 4 GBIC (Serial Identification) as defined by the
Gigabit Interface Converter specification.
Replace this transceiver with a GBIC that is qualified by 3Com.
) of this GBIC type is not a
xx