Accurex XUEF-300 Handbuch für Installation, Betrieb und Wartung - Seite 15

Blättern Sie online oder laden Sie pdf Handbuch für Installation, Betrieb und Wartung für Fan Accurex XUEF-300 herunter. Accurex XUEF-300 20 Seiten. Utility fans

Accurex XUEF-300 Handbuch für Installation, Betrieb und Wartung

Bearing Replacement

For Arrangement 10
The intent of this procedure is to allow a field service
technician to replace bearings with the fan remaining
in place in its intended application. All work can be
conducted accessing the bearings by either removing
a shaft guard, a weatherhood or working under a
weatherhood. This is dependent on the size of the
unit. This procedure assumes the power source has
been locked out prior to removing guards and covers,
belts and pulleys have been loosened and removed
properly, and extended lubrication lines have been
disconnected at the bearing. In some cases, it may
be necessary to remove the fan inlet cone and wheel
if the bearings cannot be removed due to corrosion
or damage. See Radial Gap, Overlap and Wheel
Alignment on page 10 to the realign wheel upon
installation.

Bearing Removal

This procedure assumes proper safety measures have
been taken.
• Read and follow all instructions carefully.
• Disconnect and lockout power before installation
and maintenance.
• Driven sheaves and belts have already been
removed.
• Shaft black coating can be removed with a solvent
similar to a brake/carburetor cleaner.
1. Scribe a line around the shaft by both bearings and
around the bearing base to the bearing support or
write down the measurement from the end of the
shaft to the bearings. This will help in repositioning
the new bearing and wheel cone overlap.
2. Follow the bearing manufacturers' procedures for
removal and installation.
3. Before removing the bearing bolts, make sure the
shaft is supported slightly. Remember to consider
the wheel weight on the shaft.
4. Remove both bearings from the shaft and clean/
remove any burrs using an emery cloth or file.
5. Clean mounting surface of any dirt or grease.

Bearing Installation

1. Before installing, read bearing manufacturers'
procedures. Before putting the new bearings on
the shaft, you may need to break what is called
swivel torque on the bearings (depending on style
of bearing). This is done by holding the bearing
housing securely and being able to move the
inner bearing race around freely.
2. Apply light film of oil on shaft, then gently slide
the new bearings onto the shaft.
Do not hammer bearing onto shaft!
3. Align bearings on shaft with the previous scribe
marks that are on the shaft and lock bearing to
shaft.
4. Put bolts into mounting surface and bearings. Do
not tighten.
5. Remove blocks if shaft is supported.
6. Set bearings on support with the scribed marks
locating the bearings. Make sure bearings are
square and level with the shaft.
7. Tighten bolts and torque bearing bolts, bearing
set screws/locking collars as per bearing
manufacturers' procedures.
8. Rotate shaft by hand to help allow the bearings
to help set in. At this time, listen for any unusual
noises such as wheel rubbing on cone and any
bearing noise.
9. Connect extended lube lines in new bearings if
needed.
10. Reinstall the drive sheaves and belts. Check the
belt alignment.
11. Make sure to reinstall all guards and follow proper
safety measures before starting up the fan.
Utility Fans
15