Digicode DGA Installationshandbuch - Seite 6
Blättern Sie online oder laden Sie pdf Installationshandbuch für Tastenfeld Digicode DGA herunter. Digicode DGA 20 Seiten. Surface-mount keypad - cast aluminium
INSTALLATION MANUAL
DGA
Cast aluminium Digicode
- the green LED lights during 1 second. Enter the time in 10th of second 10 for 10 seconds up to 99 for 99
seconds the backlighting dims 10 seconds after the last keypress or switches off after entering a valid code,
- enter 00 for a permanent illumination keys. The green LED lights during 1 second.
3] Press A1 to program relay 1 output time (door release time):
- the green LED lights during 1 second,
- for a timed output enter the time in seconds 01 for 1 second up to 99 for 99 seconds,
- enter 00 for a latched output,
- the green LED lights during 1 second to validate the time.
4] Press A2 to program relay 2 output time (door release time):
- the green LED lights during 1 second,
- for a timed output enter the time in seconds – 01 for 1 second up to 99 for 99 seconds,
- enter 00 for a latched output. The green LED lights during 1 second to validate the time.
5] Press B to exit from programming mode:
- the red LED lights to confirm exit from programming.
The red LED flashes 4 times to indicate a data computing error.
RESET MASTER CODE
Short the white and the yellow wires:
- the green LED lights on,
- one beep is emitted,
- wait until the green LED lights off. Separate the two wires,
- the master code is reset to the factory default value 123456 in 6-digit code length, 12345 in 5-digit
code length or 1234 in 4-digit code length.
CHANGING THE CODE BY THE USER
To authorize a user to modify its own User code short the blue and the yellow wires (Separate the two wires
to disable this function).
1] Enter the old user code:
- the relay is activated and the green LED lights on.
2] Enter the 2-digit sub master code (default sub master code A and B):
- the red LED lights on to authorize the modification.
3] Enter the new user code:
- the green LED lights during 1 second to confirm the new user code The red LED lights off.
4] Check the new user code to make sure of the modification.
SETTING A SUB MASTER CODE
The Sub Master code allows the user to change its own code without entering in programming mode. For
security reasons the code need to be changed periodically. This feature makes it easier and faster to change
its code
1] Enter the master code twice (12345 default master code):
- the red LED lights on to confirm entry in programming.
cdvi.se
6
cdvigroup.com
Self Contained
®
EN