Axxess TRIGGER Installationsanleitung Handbuch - Seite 8

Blättern Sie online oder laden Sie pdf Installationsanleitung Handbuch für Automobilelektronik Axxess TRIGGER herunter. Axxess TRIGGER 19 Seiten.

Axxess TRIGGER Installationsanleitung Handbuch
Mode 8: Double pulse latch
Description: Creates a latched signal from a double pulse signal.
Connections:
Interface wiring
Pin 5 (Orange)
Pin 6 (Green)
Pin 7 (Red)
Pin 8 (Blue)
Pin 9 (Brown)
Pin 10 (Gray)
Mode 9: Double pulse to one-second output
Description: Converts a double pulse output to a single pulse output
Connections:
Interface wiring
Pin 2 (Purple)
Pin 5 (Orange)
Pin 6 (Green)
Pin 7 (Red)
Pin 8 (Blue)
Pin 9 (Brown)
Pin 10 (Gray)
To
Ground
Negative latched output (500 mA max)
Negative latched output (500 mA max)
Positive latched output (2 amp max)
Positive double pulse input (use only one)
Negative double pulse input (use only one)
To
Ground
Ground
Negative single pulse output (500 mA max)
Negative single pulse output (500 mA max)
Positive single pulse output (2 amp max)
Positive double pulse input (use only one)
Negative double pulse input (use only one)