3. Operation
3.1 Startup
- ALWAYS ENSURE THE POWER SWITCH IS SET TO THE DISCHARGE (FORWARD) POSITION
BEFORE INSERTING THE FUSE OR BATTERY.
- NEVER INSERT THE FUSE WITH THE SWITCH IN THE ON (REARWARD) POSITION.
- It is unsafe to power up the gun with a magazine inserted
- Always check that there is nothing inside the electronics bay before powering up. Any
rounds or debris inside the bay could result in damage to the gun.
1. Ensure battery is charged to its nominal voltage of 25.2V
2. Open battery compartment by unscrewing the thumb-boltsat the rear of the gun. Gently
slide the battery compartment rearward and connect battery XT-60 connector to the gun.
3. Stuff the battery, connector and excess wires into the battery compartment. Ensure wires
clear pinch points and close the compartment by sliding the battery section forward onto
the rail mount. Slide the battery enclosure fully forward before re-tightening the bolts.*DO
NOT OVER-TIGHTEN BOLTS* One turn is sufficient to secure the battery.
10 |
P a g e