Creda Aquawave White Installations- und Benutzerhandbuch - Seite 2

Blättern Sie online oder laden Sie pdf Installations- und Benutzerhandbuch für Sanitärprodukt Creda Aquawave White herunter. Creda Aquawave White 8 Seiten. Electric shower (covers white, colour and heritage models)

Creda Aquawave White Installations- und Benutzerhandbuch
Section
Introduction . . . . . . . . . . . . . . . . . . . . . .
Important Safety Information . . . . . . . . . .
Assembly of Accessories . . . . . . . . . . . . . .
How to use your Aquawave
Contemporary Shower (Detailed) . . . . . . . .
How to use your Aquawave
Heritage Shower (Detailed) . . . . . . . . . . . .
What to do if things go wrong (1)
Self Help . . . . . . . . . . . . . . . . . . . . . . . . .

INTRODUCTION

Thank you for purchasing a quality Creda Aquawave Shower manufactured in England.
To enjoy your new shower at its best, please take time to read this manual thoroughly to
familiarise yourself with all instructions, BEFORE beginning installation.
Having done so, keep this manual handy for future reference.
Your shower is designed to stabilise temperature changes caused by water pressure fluctuations.
These can result from toilets being flushed or taps being turned on and off.
When this happens your showering temperature will be held within a controlled band, provided that
the minimum pressure required by the shower is maintained (see "Effect of Other Water Devices").
If you experience any difficulty with the installation or operation of your new
shower, then please refer to the "What to do if things go wrong" section in this
manual before contacting us.

IMPORTANT SAFETY INFORMATION

1. Your shower has been designed for convenience, economy and safety of use, provided that it is
installed, used and maintained in good working order and in accordance with our instructions and
recommendations.
2. All wiring and installation must be supervised by a suitably qualified person.
3. THIS APPLIANCE MUST BE EARTHED.
4. The installation must be in accordance with the current edition of BS.7671 (the "IEE Wiring
Regulations") and "Part P" of the "Building Regulations" in force at the time of installation.
Installations outside of England and Wales must also conform to any local regulations in effect.
This appliance is intended to be permanently connected to the fixed electrical wiring of the mains
supply with its own dedicated supply.
5. This appliance must NOT be fitted where it may be subjected to freezing conditions.
6. DO NOT switch the appliance on if you suspect it of being frozen.
Wait until you are sure it has thawed out.
7. DO NOT fit any sort of tap or control on the appliance outlet. The appliance is designed to have
an open outlet and should only be used with "Creda" recommended fittings.
8. Take care to avoid restricting the outlet of the pressure relief device. If water is discharged from
the pressure relief device, maintenance will be required before the appliance can be safely used.
9. Isolate the mains electrical and water supply before removing the front cover of the appliance.
CONTENTS
Page
Section
2
Additional Accessories and Common Parts . .
2
What to do if things go wrong (2)
Professional Service . . . . . . . . . . . . . . . . .
3
Creda After Sales Service . . . . . . . . . . . . .
5
8
How your Aquawave Shower Works . . . . . .
8
Guarantee and Contact Details . . . . . . . . . .
How to use your Aquawave
Heritage Shower (Summary) . . . . . . . . . . .
9
10
11
2
HOW TO USE YOUR AQUAWAVE HERITAGE SHOWER (SUMMARY)
Relates to the Heritage Shower Range ONLY, see unique section for Contemporary Range
Page
11
1. Ensure the electricity and water are turned on to the unit.
12
2. Press the start / stop button "B".
12
This will turn the shower on, the water will flow and the
13
neon indicator light will illuminate. It is recommended that
14
you do not wholly enter the water flow during this period.
3. Knob "A" controls the power selection.
15
Select "High", "Med (medium)" or "Cold"
16
4. If the water is not at your desired showering
temperature, turn knob "C" a small amount until you
reach the desired showering temperature.
Turn clockwise for cooler.
Turn anti-clockwise for warmer.
5. When you have finished showering, press the start / stop button "B" again.
The water will stop flowing and the neon indicator will go out.
10.5kW Models Only-Water will continue to flow for approximately 7 seconds before switching off.
6. Switch off the electricity supply at the ceiling switch or local isolator.
Notes
Wait 20 seconds for the temperature to stabilise after each adjustment.
The neon indicator light illuminates when the heaters are on and, if the shower has
been recently used, can take up to 20 seconds to come on.
During this time the water may go from very hot to cold before stabilising.
The position of knob "C" will be approximately the same each time the shower is
used, varying only with incoming water temperature or pressure changes
(e.g. you will only need to change from summer to winter).
During normal operation, if an overheated water temperature is sensed then the
heater will switch off and the neon indicator light will go out.
The water will continue to flow and cool down before the heater switches back on
again.
DO NOT SWITCH THE APPLIANCE ON IF YOU SUSPECT IT OF BEING FROZEN.
WAIT UNTIL YOU ARE SURE IT HAS THAWED OUT.
DO NOT OPERATE THE APPLIANCE IF WATER DISCHARGES FROM THE PRESSURE RELIEF
VALVE. MAINTENANCE IS REQUIRED BEFORE THE APPLIANCE CAN BE SAFELY USED.
THIS APPLIANCE IS NOT INTENDED FOR USE BY PERSONS (INCLUDING CHILDREN)
WITH REDUCED PHYSICAL, SENSORY OR MENTAL CAPABILITIES,
OR LACK OF EXPERIENCE AND KNOWLEDGE, UNLESS THEY HAVE BEEN GIVEN
SUPERVISION OR INSTRUCTION CONCERNING USE OF THE APPLIANCE
CHILDREN SHOULD BE SUPERVISED TO ENSURE THAT THEY
IMPORTANT WARNINGS!
BY A PERSON RESPONSIBLE FOR THEIR SAFETY.
DO NOT PLAY WITH THE APPLIANCE.
15