Remove battery cover and insert 2 x AAA batteries. (Observe polarity).
Ensure the rubber seal is correctly located before replacing the battery cover.
Additional remote control
More than one remote control can be configured to the same base unit.
Only one remote control will function at any one time.
(See spares for additional remotes : Page 19)
_14_
High pressure – Unvented thermal store (Non Pumped Model only)
High pressure – Combi boiler (Non Pumped Model only)
• Pressure reducing valves are required if
the pressure is above 5 bar.
• This plumbing scheme requires that the
hot water pipe to the base unit (Non
Pumped) MUST come from the output
of a combi boiler.
• The cold water supply MUST come
from a balanced pressurised supply.
• When a combi boiler scheme is used,
DIP 4 switch (inside remote control
battery compartment) MUST be set to
Off.
See "Fix the flow rate (no flow
adjustment possible)" on Page 11
Diagram of un-vented combi boiler
system
Shower cubicle
The mixed outlet pipe from the base unit is connected to the shower accessories in the shower
cubicle. (See separate installation instructions supplied with the accessories)
Fix the remote control holder in the required position.
(Avoid mounting the remote control in the direct spray from the shower handset)
Pressure reducing valves are required if
the pressure is above 5 bar.
This plumbing scheme requires that the
hot water pipe to the base unit (Non
Pumped) MUST come from the output of
the thermal store.
If required, a temperature blending valve
can be fitted on the hot outlet of the
thermal store.
The cold water supply MUST come from
a balanced pressurised supply.
Diagram of un-vented thermal store system
_7_