CREE LIGHTING Stylus Series Installationsanleitung Handbuch - Seite 6

Blättern Sie online oder laden Sie pdf Installationsanleitung Handbuch für Arbeitslicht CREE LIGHTING Stylus Series herunter. CREE LIGHTING Stylus Series 8 Seiten.

8
Flexible Conduit
Supplied By Others
Support Nut
Supplied By Others
LED Tray
Lens
9
4.25"
Ceiling opening width
for Flangeless
10
Sheetrock Mud
Supplied By Others
6 of 8
Threaded Support Rods Supplied By Others
3.37"
Ceiling opening width
overlapping flange
Threaded Support Rod
Supplied by Others
Sheetrock Mud
Supplied By Others
SECTION 3:
OFF GRID MOUNTING (HARD CEILING) -
INDIVIDUAL RECESSED MOUNTING
CAUTION: Ceiling contractor must provide an uninterrupted,
continuous rough opening. Dimensions of opening should be
determined using Figure 3 on page 3 and Figure 9.
CAUTION: Luminaires should be secured to structure above
using customer supplied threaded rods to support weight of
luminaire.
STEP 1:
Remove lens and LED/reflector tray and set aside in order
of run placement for reinstalling later. To remove lens,
carefully slide a plastic card or putty knife between the lens
and extrusion towards the end of the luminaire. Using the
plastic card or putty knife, push the lens inward until the
lens come free. After removing the lens, remove the Philips
head reflector screws, remove the LED Reflector Tray, and
disconnect the LED harness. Set lens and LED Reflector tray
aside. See Figure 2 and 8.
STEP 2:
Using one of the 7/8" dia. holes on the end of the fixture,
install conduit connector. See Figure 8.
STEP 3:
Install fixture from below into ceiling opening. Attach
customer supplied threaded rods to luminaire through 5/8"
mounting holes located on the top of the housing and to the
structure above as shown in Figure 8. Confirm that fixture is
pulled up firm to ceiling line.
STEP 4:
Make electrical connections per Section 5 "Electrical
Connections" to leads in wiring compartment.
STEP 5:
Reconnect LED harness. Replace LED trays and lens that
was removed in Step 1 above, ensure that no wires are
pinched.
STEP 6:
For Hard Ceiling, Overlap Flange Only:
Fill in Sheet Rock mud over tapered extruded flange until
smooth. See Figure 10.
#10-18 X 1/4"
Phillips Head Screws
LPN00644X0007A0_A