Cres Cor AquaTemp Handbuch für Installation, Betrieb und Wartung - Seite 10

Blättern Sie online oder laden Sie pdf Handbuch für Installation, Betrieb und Wartung für Konvektionsofen Cres Cor AquaTemp herunter. Cres Cor AquaTemp 15 Seiten. Humidity convection ovens

Convection
Humidity Oven
Page 10 of 14
Rev. 4 (6/15)
PROBLEM
Oven does not turn on
IF THE OVEN TURNS ON:
PROBLEM
Oven does not heat, or doesn't heat
properly
Blowers do not operate
Heater will not shut off
Vent fans do not shut off
Vent fans do not operate
Control will not switch from "COOK" to
"HOLD" (timed mode)
Control will not switch from "COOK" to
"HOLD" (probe mode in DX ovens only)
Control will not switch to "COOK" (probe
mode in DX ovens only)
No Humidity

ERROR CODES:

CODE DISPLAYED
no p
Err0
Err1
Call Toll-free: 877-CRES COR (273-7267) • Fax: 800-822-0393 • www.crescor.com
FL-2373
MAINTENANCE INSTRUCTIONS
TROUBLE-SHOOTING GUIDE (continued)
POSSIBLE CAUSE
1. Power switch is bad
2. Retherm control is bad.
POSSIBLE CAUSE
1. Sensor
2. Heater contactor
3. Loose wiring at heater contactor
4. Oven control
5. High Limit
1. Blower
2. Oven control
1. Control defective
2. Heater contactor
1. Vent fan switch defective
2. Control compartment is still hot.
1. Vent fan switch defective
2. Vent fan defective
1. Oven is in "PROBE" mode (DX oven)
2. Oven control defective
1. Oven is in the "TIMED" mode
2. Probe not plugged in
3. Probe defective
4. Oven control defective
1. Oven in "TIMED" mode
2. Probe temperature setting lower
than probe temperature
3. Probe not plugged in
4. Oven control defective
1. Water element defective
2. AquaTemp control
CAUSE
No meat probe
Temp probe bad
Water fill time out
5925 Heisley Road • Mentor, OH 44060-1833
SOLUTION
1. Replace
2. Replace
3. Replace
4. Replace
5. Replace
1. Replace
2. Replace
3. Replace
1. Replace
2. Replace
1. Replace
2. Wait until it cools
Check "Heater will not shut off"
1. Replace
2. Replace
1. Cancel recipe and switch to "TIMED" mode
2. Replace
1. Cancel recipe and switch to "PROBE" mode
2. Plug in probe
3. Replace
4. Replace
1. Switch to "PROBE" mode
2. Set probe temperature to desired tempera-
ture
3. Plug in probe
4. Replace
1. Replace
2. Replace
SOLUTION
Plug in probe
Replace
Connect water supply
SOLUTION
1. Replace
2. Replace