Introduction
The Access Control Module (ACM12) is designed to be used with the Digiplex EVO
System control panels. Each ACM12 allows you to connect a reader, a REX device, a
door contact and a locking device to control the access to one door. If desired, door
contacts can also be assigned to zones in the control panel to link the doors to the
alarm system. This will allow you to use the same door for the access control
system and the alarm system.
What's New 4.2
Support for six additional schedule intervals for Door Unlock Schedule.
Added security when disarming your system. New option to disarm with
access card and PIN code.
Technical Specifications
AC Power:
16Vac, 20/40VA, 50 - 60Hz
Aux. Power:
12Vdc, typical 600mA, 1A max.
Battery:
12Vdc, 4Ah minimum
2; one 50mA PGM output, one form C relay rated at
No. of Outputs:
5A/28Vdc, N.O./N.C.
No. of Zones:
2 (Door Contact & REX device)
No. of Inputs:
2 (Negative Trigger & Tamper inputs)
Control Panel
Any EVO control panel
Compatibility:
Installation
The module is connected to the control panel's combus as shown in Figure 1.
Please refer to the control panel's Programming Guide for the maximum
installation distance. Devices connected to the PGM output must be connected as
shown in Figure 2. Refer to Figure 5 for connection drawings for the REX device,
reader, locking device and door contact.
The door contact follows the control panel's EOL definition. When EOL is
enabled and the door contact is not used, place a 1k
resistor across the
and
- input terminals. If EOL is disabled, use a jumper. If the REX device is
AUX
not used, place a jumper across the
and
- terminals.
REX
AUX
AC Power
Use a 16.5Vac (50/60 Hz) transformer with a minimum 20VA. as shown in
Figure 1. Do not use any switch-controlled outlets to power the transformer.
Backup Battery
To power the module's door lock relay during a power failure, connect a
12Vdc 4Ah rechargeable acid/lead or gell cell backup battery as shown in
Figure 1. Connect the battery after applying AC power.
Inverting the polarity when installing the battery will blow the battery
fuse.
Connecting the External Negative Trigger
The ACM12 comes with an external negative trigger. You can use a PGM from
the control panel or another module to release the access control door lock.
The external negative trigger can also be triggered using a push-button.
When the push button is pressed, the door will unlock. The PGM or push-
button must ground the negative trigger. Connect the push-button as shown
in Figure 2.
LED Display
AC (Green):
On when receiving AC power.
BATT (Green):
On when charging and during battery tests.
AUX (Yellow):
On when auxiliary output is active.
ERROR (Red):
Indicates a problem with the module.
RX (Green):
Flashes when receiving information from the panel.
TX (Green):
Flashes when transmitting information to the panel.
Table 1: Special Display
Error
RX
TX
Condition
ON
OFF
OFF
Combus is shorted / No clock / No data
Wrong data / Invalid Combus address
ON
OFF
ON
(Too many modules)
ON
ON
OFF
Future Use
ON
ON
ON
Combus lines reversed (YEL and GRN)
Flash
----
----
Combus power is too low
Connection Diagrams
Figure 1: Connecting the power and combus
Disconnect the battery before
replacing the fuse.
12Vdc
Rechargeable Battery:
AWG #14 single
12V 4Ah min
conductor solid
copper wire
To metallic enclosure
Cold water pipe
grounding
Ground clamp
Transformer Sharing
Transformer Sharing: Use one transformer to power
multiple modules with transformer sharing.
Connect to another
CT
module compatible with
From
transformer sharing
transformer
Figure 2: Additional Connection Information
To PGM output
And / Or
External Negative Trigger
AUX switch:
Press to toggle the AUX output.
Figure 3: Connecting a 4-Wire Reader (R910 / R915)
If the ACM12 loses
communication with the
reader, it will show up as a
Combus
Module Fail to Com. trouble.
Digiplex/
Connected up to 300m
(1000ft) away.
Digiplex EVO
series control
panel
Reader
ACM-12
1: RED
to
(+)
2: BLK
to
(-)
3: GRN
to
(D0)
4: YEL
to
(D1)
Only connect one reader per ACM12
Figure 4: Connecting a 7-Wire Routing Cable
If you use a routing cable, use a shielded
routing cable. Do not connect the routing
cable's shield to the reader's shield. Only
connect the routing cable's shield at the
ACM12.
Connected up to 152m
(500ft) away.
Connect
Reader
ACM-12
1: Red
to
(+)
2: Black
to
(-)
3: Green
to
(D0)
4: White
to
(D1)
5: Brown
to
(Beep)
6; Orange
to
(RED)
7: Yellow
to
(GREEN)
Only connect one reader per ACM12
Figure 5: Connecting Access Control Devices
External Tamper
Switch (N.C.)
When connecting the diode to the door lock, be sure to
connect the cathode of the diode to the positive (+)
PGM
voltage and the anode to the negative (-) voltage.
Cathode
1N4007
Diode
Anode
Figure 6: Connecting for Firmware Upgrade (CONV4USB)
ACM12
R915
R910 (not shown) is connected the same way
CR-R880-BL
CR-R885-BL (not shown) is connected the same way
No EOL required
on REX
** Door contact
must be
*** REX device must be
connected to
CT
connected to
terminal
REX
terminal
* = Follows control panel's EOL definition.
** = If the door contact is not used, install a jumper or a 1k
resistor across the
- and
terminals depending on the
AUX
CT
control panel's EOL definition.
*** = If the Request for Exit (REX) device is not used, place a
jumper across the
- and
terminals.
AUX
REX
CV4USB