Cisco C-series Nexus 5020 Freigabemitteilung - Seite 18
Blättern Sie online oder laden Sie pdf Freigabemitteilung für Schalter Cisco C-series Nexus 5020 herunter. Cisco C-series Nexus 5020 26 Seiten. Replacing an i/o module nexus 5000 series
Auch für Cisco C-series Nexus 5020: Spezifikationen (3 seiten), Datenblatt (23 seiten), Freigabemitteilung (3 seiten), Handbuch (11 seiten), Hardware-Installationshandbuch (19 seiten)
Caveats
S e n d d o c u m e n t a t i o n c o m m e n t s t o n e x u s 5 k d o c s @ c i s c o . c o m
•
•
•
•
Resolved Caveats—Cisco NX-OS Release 4.0(1a)N1(1a)
This section lists the resolved caveats for this release.
•
Cisco Nexus 5000 Series Release Notes, Release 4.0(1a)N1(1a)
18
Workaround: Configure a shorter query interval on the IGMP router to reduce the time it takes for
ip-multicast traffic to converge in this topology.
CSCsq35728
Symptom: When a SAN port channel is created, the following syslog message is displayed:
2008 May 20 06:09:13 switch %PORT_CHANNEL-3-MSG_SEND_FAILURE: failed to send
MAP_PARAM_FROM_CHANNEL to sap 45: Broken pipe"
There is no functionality loss and this message can be ignored.
Workaround: None.
CSCso01268
Symptom: The following error message is displayed when a module is hot-swapped out:
2005 Jan
1 00:08:23 switch %KERN-4-SYSTEM_MSG: SI-VDC map entry <0, 0x0> does not
exist! - kernel"
There is no functionality loss and the message can be ignored.
Workaround: None.
CSCsq57558
Symptom: Enhanced Inter Switch Link (EISL) encapsulation is not supported on a Fibre Channel
SPAN destination port. When EISL encapsulation is configured on the SPAN destination (SD) port,
a VFT header is added to the packets going out of the SD port. The VFT header has VSAN
information that helps distinguish traffic for various VSANs. This applies to any Fibre Channel
SPAN source. By default, EISL encap is not added and packets are sent out without a VFT header,
and independent of the type of SPAN source port. For a Nexus 5000 Series switch, the switchport
encap EISL command does not have any effect.
Workaround: Use the Ethernet SPAN destination port to SPAN Fibre Channel traffic. FCoE packets
going out of the Ethernet SPAN destination port will contain VSAN information in the Ethernet
VLAN tag.
CSCsq90423
Symptom: EISL encapsulation is not supported on Fibre Channel SPAN destination port in NPV
mode. When EISL encapsulation is configured on the SPAN destination (SD) port, a VFT header is
added to the packets going out of the SD port. The VFT header has VSAN information, which helps
distinguish traffic for various VSANs. This applies to any Fibre Channel SPAN source. By default,
EISL encapsulation is not added and packets are sent out without a VFT header, and independent of
the type of SPAN source port. For a Nexus 5000 Series switch, the switchport encap EISL
command does not have any effect.
Workaround: Use the Ethernet SPAN destination port to SPAN Fibre Channel traffic. FCoE packet
going out of the Ethernet SPAN destination port will contain VSAN information in the Ethernet
VLAN tag.
CSCsy65407
Symptom: In the Cisco NX-OS 4.0(1a)N1(1) release, if an RBAC role has more than 67 rules
configured, show running-config causes the vshd process to core dump. This caveat exists in the
4.0(0)N1(2a) and 4.0(1a)N1(1) releases.
OL-16601-01