FIBARO FGMS-001 Betriebshandbuch - Seite 4
Blättern Sie online oder laden Sie pdf Betriebshandbuch für Zubehör FIBARO FGMS-001 herunter. FIBARO FGMS-001 11 Seiten. Motion sensor
Auch für FIBARO FGMS-001: Betriebshandbuch (20 seiten), Betriebshandbuch (2 seiten)
6
#3: Adding/removing the device
Adding (Inclusion) - Z-Wave device learning mode, allowing to add
i
NOTE
the device to existing Z-Wave network.
Adding
in
security
To add the device to the Z-Wave network:
mode must be per-
formed up to 2 meters
1. Open the cover.
from the controller.
2. Place the Motion Sensor within the direct range of your Z-Wave
controller.
i
NOTE
3. Set the main controller in (security/non-security) add mode (see
the controller's manual).
In case the Sensor is
4. Quickly, three times press the B-button.
not added, please re-
set the Sensor and re-
peat the adding pro-
cedure.
B-button
5. Wait for the adding process to end.
6. Successful adding will be confirmed by the Z-Wave controller's
message.
Removing (Exclusion) - Z-Wave device learning mode, allowing to
i
NOTE
remove the device from existing Z-Wave network.
Removing the device
To remove the device from the Z-Wave network:
from the Z-Wave net-
work restores all the
1. Open the cover.
default parameters of
2. Place the Motion Sensor within the direct range of your Z-Wave
the device.
controller.
3. Set the main controller in remove mode (see the controller's
manual).
4. Quickly, three times press the B-button.
B-button
5. Wait for the removing process to end.
6. Successful removing will be confirmed by the Z-Wave controller's
message.
ADDInG/REMOvInG ThE DEvICE
#4: Physical installation
Detection range:
Detection range of the Motion Sensor is shown below. Actual range
of the Sensor can be influenced by environmental conditions.
5 m
3 m
0 m
0 m
7 m
5 m
Installation location and working conditions:
The Motion Sensor should be installed in a corner of the room or per-
pendicularly to the doors.
Moving objects such as trees blowing in the wind, cars passing by,
windmills and moving masses of air and heat within detection area
of the sensor can cause false motion detection.
Installing the Motion Sensor:
1. Install the holder (using an expansion bolt or a sticker).
2. Insert the device into the holder.
3. Test the operation - check whether the device indicates motion
detection.
7
i
NOTE
Remember to add the
device to the Z-Wave
network prior to in-
stallation, as the add-
ing procedure must
be performed within
the direct range of the
controller.
7 m
Sticker
PhySICAL InSTALLATIOn