This parameter defines which frames will be sent in the 2-nd Association Group (FIRE ALARM). The values of BASIC ON and BASIC OFF frames may be defined
as described in further parameters.
Size: 1 Byte, Default Value: 0
Setting
0
1
2
Parameter 11: BASIC ON frame value
BASIC ON frame is sent in case of smoke presence detection and Fire Alarmtriggering. Its value is defined by the parameter.0 turn off the device.
Size: 2 Byte, Default Value: 255
Setting
0 - 99
255
Parameter 12: BASIC OFF frame value
BASIC OFF frame is sent in case of Fire Alarm cancellation. Its value is defined by the parameter.0 turn off the device1-99 set the device to 1-99%255 set the last
status
Size: 2 Byte, Default Value: 0
Setting
0 - 99
255
Parameter 13: Alarm broadcast
A value other than 0 means that alarms are being sent in broadcast mode, i.e. to all devices within a FIBARO Smoke Sensor's range.
Size: 1 Byte, Default Value: 0
Setting
0
1
2
3
Parameter 20: Temperature report interval
Time interval between consecutive temperature reports.
Report is sent when new temperature value is different from the one previously reported – according to the set hysteresis (parameter 21). Temperature reports can
be also sent as a result of polling.
Size: 2 Byte, Default Value: 1
Setting
0
1 - 8640
Parameter 21: Temperature report hysteresis
The temperature report will only be sent if there is a difference in temperature valuefrom the previous value reported, defined in this parameter
(hysteresis).Temperature reports can be also sent as a result of polling.
Size: 1 Byte, Default Value: 10
Setting
1 - 100
Parameter 30: Temperature threshold
Temperature value measured by the built-in temperature sensor above which the excess temperature notification is sent (visual indication/sound/Z-Wave report).
CAUTION: Parameters 30, 31 and 32 are associated with parameters 2, 3 and 4 settings. Their modification may have no effect if configured functionality is not
activated in the corresponding parameter.
Size: 1 Byte, Default Value: 55
Setting
1 - 100
https://manual.zwave.eu/backend/make.php?lang=en&sku=FIBEFGSD-002
https://manual.zwave.eu/backend/make.php?lang=en&sku=FIBEFGSD-002
Description
BASIC ON & BASIC OFF enabled
BASIC ON enabled
BASIC OFF enabled
Description
set the device to 1-99%
set the last status
Description
set the device to 1-99%
set the last status
Description
broadcast inactive
FIRE ALARM broadcast (2nd & 4th Association Group) active; enclosure opening notification broadcast (3rd &
5th Association Group) inactive
FIRE ALARM broadcast (2nd & 4th Association Group) inactive; enclosure opening notification broadcast (3rd &
5th Association Group) active
FIRE ALARM broadcast (2nd & 4th Association Group) active; enclosure opening notification broadcast (3rd &
5th Association Group) active.
Description
reports inactive
[10s-24h] Default setting: 1 (10 seconds)
Description
(multiply by 0.1) [0.1°C – 10°C] Default setting: 10 (1°C)
Description
(1°C – 100°C)
6/8