Auch für Sharp Carousel R-1514: Broschüre & Specs (8 seiten), Installationsanleitung Handbuch (40 seiten), Broschüre & Specs (5 seiten), Installationsanleitung Handbuch (9 seiten), Spezifikationen (2 seiten), Zusätzliches Servicehandbuch (33 seiten), Handbuch zum Kochen (32 seiten), Handbuch (40 seiten), Zusätzliches Servicehandbuch (33 seiten)

Sharp Carousel R-1514 Handbuch zum Kochen
S E R V I C E C A L L C H E C K
Please check the following before calling for service:
Place one cup of water in a glass measuring cup in the oven and close the door securely.
Operate the oven for one minute at HIGH 100%.
A Does the oven light come on?
B Does the cooling fan work?
(Put your hand over the left side of louver.)
C Does the turntable rotate?
(It is normal for the turntable to turn in either direction.)
D Is the water in the oven warm?
If "NO" is the answer to any of the above questions, please check electrical outlet, fuse and/or circuit
breaker. If they are functioning properly, CONTACT YOUR NEAREST SHARP AUTHORIZED SERVICER.
A microwave oven should never be serviced by a "do-it-yourself" repair person.
NOTE: If time appearing in the display is counting down very rapidly, check Demonstration Mode on page 21
and cancel.
S P E C I F I C A T I O N S
AC Line Voltage:
AC Power Required:
Output Power:
Frequency:
Outside Dimensions:
Cavity Dimensions:
Oven Capacity:**
Cooking Uniformity:
Weight:
The International Electrotechnical Commission's standardized method for measuring output wattage. This
test method is widely recognized.
Internal capacity is calculated by measuring maximum width, depth and height. Actual capacity for holding
★★
food is less.
In compliance with standards set by:
FCC
– Federal Communications Commission Authorized.
DHHS
– Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21, Chapter I,
Subchapter J.
– This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc.
R-1520L, R-1514
Single phase 120V, 60Hz, AC only
1600 watts, 14.0 amps.
1000 watts* (IEC Test Procedure)
2450 MHz
29
/
"(W) x 16
/
"(H) x 15
15
1
16
4
17
/
"(W) x 9
/
"(H) x 14
1
7
2
8
1.5 Cu. Ft.
Turntable system, diameter 14
Approx. 55 lb
25
YES _______
YES _______
YES _______
YES _______
/
"(D)
9
16
/
"(D)
15
16
/
"
1
8
NO _______
NO _______
NO _______
NO _______