The cable break detector can be implemented utilizing one or both of the APU channels. If only one
channel is used, the other channel is typically "jumpered-out," which means that a short single-mode
or multi-mode jumper would be used to close the loop of the unused channel; that way, either the Fault
indicator or the Alarm indicator can be used with the functioning channel. Both channels share a
common Fault relay so if one of the two channels was not connected, the Fault relay would
permanently be in a fault state, and a red light would signal a fault on the unused channel. The primary
purpose of "jumpering-out" the unused channel is to satisfy the unused channel and prevent the red
LED from illuminating.