5. Please confirm that computer and device have been properly
connected.Launch the GUI application, click Button "Online" in
the menu,and select"USB" or "COM" to connect the device,
which depends on how you actually connected the interface.
GUI software Notes
All the panel buttons and the knobs cannot be controlled when the
device is connected to the GUI.
No need to select which one serial port, software can
automatically search.
USB driver free.
GUI software can set all the parameters of the device.
Please refer to the help documentation for the GUI software
operation instructions.
Necessary online control tips:
Before the user is online control operation, be sure to read the
following notes in detail:
Otherwise it will increase the risk of abnormal conditions such as
offline, computer damage, and so on when you are online:
1.In order to ensure the normal operation of the device, please
firstly check AC power if in the range of the device.
2.If conditions permit, AC power outlet needs to have the
grounding connection settings. And use a grounding power
connected to the computer and the device.
3.The same model and the same version of GUI software don't
repeatedly install.
4. All of the GUI software don't install in the same directory.
5. To avoid the use in strong interference and strong magnetic
field environment.
6.The following acts may lead to the failure of online control, and
even damage the device or your computer:
1) Before the implementation of online, Please do not plug in or
pull out the line connected the device after it is turned on.
2) After the success of online, please do not move the computer,
device and control line.
3) After the success of online, please do not operate by panel;
including touching any keys on the device.
4) After the success of online, please do not go to plug the device
or personal computer online connector.
5) After the success of online, please do not open the same type
of online control software in the computer.
6) After the success of online, please do not use a computer to
control many different device.
7. Please refer the important security matters content from the
manual.
Available online computer
Available online interface
Accessories
Description
RS232C Cable
USB Cable
Product soft ware CD
Product us age guide (This document)
Rem ote
Frequent troubleshooting guidelines
Issues
LCD monitor no
1.Check the power cable is
display, light-
connected correctly.
emitting diodes
2. Check the fuse is burned.
(LED)are dark
3. Check the power switch is closed.
1. Check the communication cable is
connected correctly
GUI cannot be
2. If you use the RS232C port in the back of
online with
the device, make sure that USB cable is not
device
connected.
3.Reopen the GUI software and reconnect the
communication cable.
1. Check all the input signals are normal.
2. Check all the output connection is correct,
include power amplifier and loudspeakers.
3. Restart the device.
No sounds output
4. Restore to factory status, Please refers to
the relevant chapter above.
5. Try to restart the device many times is still
unable to solve the fault, please contact the
distributor to resolve
1.Restart the device.
2. Restore to factory status, Please
LCD displays
refers to the relevant chapter above.
fault tips,"error
3. Try to restart the device many times is
xx"
still unable to solve the fault, please
contact the distributor to resolve
1. Restart the device
LCD displays
2. Try to restart the device many times is
fault tips:
still unable to solve the fault, please
"Storage error"
contact the distributor to resolve
1. Restart the device
LCD display
2. Try to restart the device many times is
fault tips:
still unable to solve the fault, please
"DSP1 error"
contact the distributor to resolve
Ground
ACPower Grounding
Quanti ty
1
1
1
1
1
Troubleshooting method
7