Sharp 14D2-S Service-Handbuch - Seite 26

Blättern Sie online oder laden Sie pdf Service-Handbuch für TV Sharp 14D2-S herunter. Sharp 14D2-S 41 Seiten. Colour television

Sharp 14D2-S Service-Handbuch
14D1-S/G/W
14D2-S/G

DESCRIPTION OF SCHEMATIC DIAGRAM

SAFETY NOTES:
1. DISCONNECT THE AC PLUG FROM THE AC OUTLET BEFORE
REPLACING PARTS.
2. SEMICONDUCTOR HEAT SINKS SHOULD BE REGARDED AS
POTENTIAL SHOCK HAZARDS WHEN THE CHASSIS IS OP-
ERATING.
IMPORTANT SAFETY NOTICE:
PARTS MARKED WITH "
MAINTAINING THE SAFETY OF THE SET. BE SURE TO REPLACE
THESE PARTS WITH SPECIFIED ONES FOR MAINTAINING THE
SAFETY AND PERFORMANCE OF THE SET.
SERVICE PRECAUTION:
THE AREA ENCLOSED BY THIS LINE (
CONNECTED WITH AC MAINS VOLTAGE.
WHEN SERVICING THE AREA, CONNECT AN ISOLATING TRANS-
FORMER BETWEEN TV RECEIVER AND AC LINE TO ELIMINATE
HAZARD OF ELECTRIC SHOCK.
å
" (
) ARE IMPOTANT FOR
—– - —–
) IS DIRECTLY
NOTES:
1. The unit of resistance "ohm" is omitted.
(K = 1000 ohms, M = Mega ohm).
2. All resistors are 1/10 watt, unless otherwise noted.
µ
3. All capacitors are
F, unless otherwise noted. (P =

VOLTAGE MEASUREMENT CONDITIONS:

1. Voltages in parenthesis measured with no signal.
2. Voltages without parenthesis measured with 3mV B & W or Col-
our signal.
3. All the voltages in each point are measured with VTVM.

WAVEFORM MEASUREMENT CONDITIONS:

1. The colour bar generator signal of 2.0V peak applied at of Base
Video Buffer Amp. Q252.
2. Approximately 4V AGC bias .
28
µµ
F).