Sharp SJ-44L-WH2 Service-Handbuch - Seite 8
Blättern Sie online oder laden Sie pdf Service-Handbuch für Kühlschrank Sharp SJ-44L-WH2 herunter. Sharp SJ-44L-WH2 28 Seiten. Sharp refrigerator-freezer service manual
SJ-44L
SJ-48L
SJ-44L-WH1,SJ-48L-WH1
ITEMS
Thermostat
Defrost thermostat
Thermo. fuse
Fan motor
Defrost heater
Door switch
Damper thermostat
Defrost timer
Lamp socket
Lamp
Compressor
Starting relay
Overload relay(Protector) 4TM771RFB
SJ-44L-WH2,SJ-48L-WH2
ITEMS
Thermostat
Defrost thermostat
Thermo. fuse
Fan motor
Defrost heater
Door switch
Damper thermostat
Defrost timer
Lamp socket
Lamp
Compressor
Starting relay
Overload relay(Protector) 1.8C36A1
LIST OF ELECTRICAL PARTS
TYPE NAME
MM1-8149
125V 6A
250V 3A
S101
250V 8A
SF70E
250V 10A
3R00171
110-120V 60Hz
MM1-4266
120V 94.5Ω
DSD-5
125V 0.5A
MM1-6173
—
TMDFX04FB2
110-127V
50/60Hz
—
250V 1A
—
130V 15W
FGI85HAK
115V/60Hz
PTH7M4R7MC1
—
—
TYPE NAME
MM1-8149
125V 6A
250V 3A
S101
250V 8A
SF70E
250V 10A
3R00121A
220-240V 50/60Hz
220-240V 378 Ω
MM6-4264
DSD-5
250V 0.25A
MM1-6173
—
ND1004M2
220-240V
50/60Hz
—
250V 1A
—
240V 15W
FL1568SD
220-240V/50Hz
PET0SAT
—
—
RATING
(At normal notch)
ON/OFF : -20 / -25˚C
Open/Close : 8 / 1˚C
Working temp. : 70˚C
Working with ø100 fan
140W at 115V
4 terminals push-button type
Open/Close : 5 / 0˚C
Integration type
Cycle time : 12h/10h(50/60Hz)
Delay time : 4m48s/4m(50/60Hz)
E-12(Hard plastic body type)
E-12
Cooling capacity : 243W
Main coil : 1.78Ω
Aux. coil : 6.8Ω
(at 25˚C)
4.7 Ω 180V
Open/ Close : 130/61˚C
RATING
(At normal notch)
ON/OFF : -20 / -25˚C
Open/Close : 8 / 1˚C
Working temp. : 70˚C
Working with ø100 fan
140W at 230V
4 terminals push-button type
Open/Close : 5 / 0˚C
Integration type
Cycle time : 10h44m/8h57m(50/60Hz)
Delay time : 4m20s/3m37s(50/60Hz)
E-12(Hard plastic body type)
E-12
Cooling capacity : 188W(50Hz)
Main coil : 13.3Ω
Aux. coil : 25.6Ω
(at 25˚C)
22 Ω 300V
Open/ Close : 130/60˚C
8
SPECIFICATIONS
Common
Aux. coil
Main coil
SPECIFICATIONS
Common
Aux. coil
Main coil