ITEMS
Thermostat
Defrost thermostat
Thermo. fuse
F-fan motor
R-fan motor
(R-fan fuse)
Defrost heater
Door switch
Damper thermostat
Defrost timer
Lamp socket (F/R)
F-lamp
R-lamp
R-fan thermo. R-fan thermo.
ass'y
R-fan thermo.heater
Compressor
Starting relay
Overload relay(Protector) 4TM771RFBZZ
LIST OF ELECTRICAL PARTS
TYPE NAME
MM1-8123
125V 6A
250V 3A
US-602S
250V 8A
SF70E
250V 10A
3R00044A
100V 50/60Hz
110V 60Hz
3R00122B
100V 50/60Hz
127V 50/60Hz
123
250V 2A
MM6-4199D
105V 150W
DSD-5
125V 0.5A
MM1-6170
—
TMDFX04FB2
110-127V
50/60Hz
—
250V 1A
—
110V 10W
—
110V 15W
S101
125V 15A
RSS2
2W (1.2W 110V)
FGI85HAK
115V/60Hz
RTH7M4R7MC1
—
—
RATING
(At normal notch)
ON/OFF : -19/-24˚C
Open/Close : 10/1˚C
Working temp. : 70˚C
Working with ø100 fan
Working with ø80 fan
Cut OFF 130˚C
With deodorizer
4 terminals push-button type
Open/Close : 3.0/-2.0˚C
Integration type
Cycle time : 12/10 hours(50/60Hz)
Delay time : 4.8/4.0 min.(50/60Hz)
E-12(Hard plastic body type)
E-12
E-12
Open/ Close : 7/ 15 ˚C
10kΩ
Cooling capacity : 209kcal/h(60Hz)
Main coil : 1.78Ω
Aux. coil : 6.8Ω
(at 25˚C)
+
4.7Ω
20% 180V
Open/ Close : 130/61˚C
5
SPECIFICATIONS
Main coil
Aux. coil
Common
SJ-58L-A2
SJ-63L-A2
SJ-68L-A2/R2