Digital Electronics Corporation APL3700-TA Installationshandbuch - Seite 10
Blättern Sie online oder laden Sie pdf Installationshandbuch für Industrie-PC Digital Electronics Corporation APL3700-TA herunter. Digital Electronics Corporation APL3700-TA 17 Seiten.
RAS Interface
• Be sure to use only the rated voltage
level when using pin #1 (+12V) for
external power output. Failure to do so
can lead to a unit malfunction or acci-
dent.
Interfit Bracket #4-40 UNC
Pin # Signal Name
1
+12V
2
DOUT0(+)
3
DOUT1(+)
4
DIN0(+)
5
DIN1(+)
6
GND
7
DOUT0(-)
8
DOUT1(-)
9
DINCOM
*1 Can be used as reset input.
• For the circuit diagram, refer to "PL3000
Series Reference Manual".
Installations
• Before installing the PL unit on the
panel, detach the control box from the
front module to configure the settings
of the internal switches.
SEE
Installation/uninstallation of the
front module and the control
box, Internal Switches
1.
Installation Requirements
• For easier maintenance, operation, and
improved ventilation, be sure to install the
Meaning
Output Current:
100mA or less
Output Voltage:
12V±5%
Data out 0(+)
Data out 1(+)
Data in 0(+)
*1
Data in 1(+)
Ground
Data out 0(-)
Data out 1(-)
Data in ground
common
PL at least 50mm [1.97 in.] away from
adjacent structures and other equipment.
For the face to which the cable is con-
nected, however, a space of 120 mm [4.72
in.] or more is necessary for cable curve.
50
[1.97]
50
[1.97]
50
[1.97]
• Be sure that the surrounding air tempera-
ture and the ambient humidity are within
their specified ranges.
When installing the PL on the panel of a
cabinet or enclosure, "Surrounding air tem-
perature" indicates both the panel face and
cabinet or enclosure's internal temperature.
Panel face
50
[1.97]
[1.18]
• Be sure that heat from surrounding equip-
ment does not cause the PL to exceed its
standard operating temperature.
2.
PL Installation
(1) Create a Panel Cut following the dimen-
sions in the following table. Also, deter-
mine the panel thickness according to the
panel thickness range with due consider-
ation of panel strength.
Unit:mm[in.]
PL
10
Unit:mm[in.]
50
[1.97]
50
[1.97]
50
[1.97]
Cabinet
interior
30
30
[1.18]
Under
X
4-R3 [0.12]
Y
120
[4.72]
unit:mm[in.]
Panel
thickness