Digital Equipment SA100 Installations- und Benutzerhandbuch - Seite 16
Blättern Sie online oder laden Sie pdf Installations- und Benutzerhandbuch für Lagerung Digital Equipment SA100 herunter. Digital Equipment SA100 16 Seiten. Storage subsystem
See the Tx857 Series Magazine Tape Subsystem Owner's Manual
for information on power-on self-test (POST) for the magazine tape
subsystem.
4.1 Diagnostics
There are two SA100 subsystem diagnostics, ILTAPE and ILEXER:
•
In-Line Tape Diagnostic (ILTAPE) — A canned sequence
diagnostic that tests the SA100 functions by using the basic tape
commands.
•
In-Line Exerciser (ILEXER) — This diagnostic exercises from 1 to
10 units in any combination of disk and drives connected to an HSC.
Logic is tested by writing and reading predetermined data patterns
and recording modes.
ILTAPE and ILEXER are run from the HSC ASCII port. See the
appropriate HSC user documentation for more information.
Perform the following procedure to test the SA100:
1. Run ILTAPE for three passes. No errors are allowed. (When both
STI ports are used, run ILTAPE through the second port for one pass
also.)
2. Run ILEXER for 15 minutes. (When both STI ports are used, run
ILEXER through the second port for 15 minutes also.)
Acceptance Testing
4
4–1