Installation and operation
3.1
Notes on installation
Note
Before you install the transponders, read this section carefully to ensure problem-free
installation and commissioning.
The transponders can only be used in conjunction with the RTLS localization system. You
can obtain the radio address of the RTLS5201T via the data matrix code printed on the
transponder or via the identifier "Addr".
You can secure the transponder with two M3 screws (torque 0.8 to 1.0 Nm) or with cable
ties (maximum width 3.5 mm) in the four side lugs. Alternatively, you can also attach the
transponder with an adhesive pad. When using an adhesive pad for fastening, ensure that
the opening on the back (1 mm hole) is not closed and thereby allows pressure equalization.
Install the transponder in such a way that it has a direct line-of-sight connection to the
gateways (360° panorama view). Any type of material can impact wireless localization.
Wireless localization through metal is not possible. In this case, localization via wireless
reflections can occur, which results in inaccurate determination of the location. You can find
additional information on this in the "Reflections and interference" section.
Check the transponder for damage before installation. The specified operating temperature
ranges must be observed.
The transponder is powered by a lithium battery (not included in the scope of delivery).
Fires and burns
Improper handling of batteries can lead result in fires and burns.
The enclosure of the transponder must not be squashed, punctured or exposed to other
mechanical influences. It may only be opened to change batteries.
Never expose the transponder to fire, temperatures above 65 °C or permanent direct sunlight.
Inserting or replacing batteries
The transponder batteries can only be replaced in dry environments. Make sure that the battery
is inserted with the poles in the correct direction.