Siemens SIWAREX R Betriebsanleitung - Seite 22
Blättern Sie online oder laden Sie pdf Betriebsanleitung für Industrielle Ausrüstung Siemens SIWAREX R herunter. Siemens SIWAREX R 34 Seiten. Mounting units for sb series
Auch für Siemens SIWAREX R: Betriebsanleitung (38 seiten)
5
Technical Data
5.1
Functional Data
Possible applicatons
Type
Rated load/maximum load E
max
Accuracy class according to OIMLR60
Max. scale interval n
LC
Min. scale interval V
min
Minimum application range R
min(LC)
Combined error F
comb
Deviation F
v
Return of zero signal
Creepage error F
cr
•
30 min
•
20 to 30 min
Temperature coefficient
•
Zero signal T
Ko
•
Characteristic value T
Kc
Min. initial loading E
min
Max. work load L
u
Break load L
d
Max. lateral load L
lq
Rated measuring path h
at E
n
max
Overload protection
Supply voltage U
(reference value)
sr
Supply voltage (range)
Rated characteristic value C
n
Tolerance D
of characteristic value
c
Tolerance D
of zero signal
o
Input resistance R
e
Output resistance R
a
Insulation resistance R
is
Rated temperature range B
tn
Operating temperature range B
Storage temperature range B
ts
Sensor material (DIN)
Degree of protection to DIN EN 60529,
IEC 60529
Max. tightening torque of the fixing
screws
2)
Current calibration
3)
EEx (i) certification
1)
For rated temperature -10 to +40 °C
2)
Current calibration: nominal characteristic value and output resistance are adjusted so that the output current is calibrated within
0.05 % of a reference value. This makes it easier to connect several load cells in parallel.
3)
Optional
4)
EEx(d) version on request (only 40/60 t)
SIWAREX R Load Cells Operating Manual
A5E00159640
BB series
Container, Conveyor,
platform scales
Bending beam
10/20/50/100/200/350 kg
C3
3000
/15000
E
max
20 %
≤ ± 0.02 % C
n
≤ ± 0.01 % C
n
1)
≤ ± 0.0167 % C
n
1)
≤ ± 0.0245 % C
n
1)
≤ ± 0.0053 % C
n
≤ ± 0.0045 % C
/5K
n
≤ ± 0.0045 % C
/5K
n
0 % E
max
150 % E
max
300 % E
max
100 % E
max
0.3 ± 0.03 mm
-
10 V
5 to 15 V
2 mV/V
± 1 %
≤ ± 1 % C
n
460 Ω ± 50 Ω
350 Ω ± 3.5 Ω
≥ 5000 MΩ
-10 to +40 °C
-40 to +80 °C
tu
-40 to +90 °C
Stainless steel 1.4542
IP 66/IP 68
23 Nm
Standard
EEx ib II C T6
CC series
Container, hopper,
vehicle scales
Pressure force
10/25/40/60 t
100 t
C3
C1
3000
1000
/12500
E
E
max
max
24 %
10 %
≤ ± 0.02 % C
≤ ± 0.03 % C
n
≤ ± 0.01 % C
≤ ± 0.02 % C
n
1)
≤ ± 0.0167 % C
≤ ± 0.05 % C
n
1)
≤ ± 0.0245 % C
≤ ± 0.049 % C
n
1)
≤ ± 0.0053 % C
≤ ± 0.0105 % C
n
≤ ± 0.0056 % C
/5K
≤ ± 0.007 % C
n
≤ ± 0.0045 % C
/5K
≤ ± 0.0085 % C
n
0 % E
max
150 % E
max
400 % E
max
10 % E
max
max. 0.36 mm
-
10 V
5 to 25 V
2 mV/V
± 1 %
≤ ± 1 % C
n
450 Ω ± 4.5 Ω
480 Ω ± 4.8 Ω
≥ 5000 MΩ
-10 to +40 °C
-40 to +80 °C
-40 to +90 °C
Stainless steel 1.4542
IP 66/IP 68
-
Standard
EEx ib II C T6
K series
Container, hopper scales
Pressure force
2.8/6/13/28/60/130/280 t
0.2%
/10000
< 0.2 % C
n
-
n
1)
-
n
1)
-
n
1)
-
n
/5K
≤ ± 0.25 % C
n
/5K
≤ ± 0.25 % C
n
0 % E
max
120 % E
300 % E
10 % E
max
0.23 to 2.67 mm
-
6 V
6 to 12 V
1.5 mV/V
± 0.5 %
≤ ± 1.5 % C
etwa 275 Ω
245 Ω ± 0.2 Ω
≥ 20 MΩ
-10 to +60 °C
-20 to +70 °C
-30 to +80 °C
Steel. painted
IP 65
-
-
4)
-
n
/5K
n
/5K
n
max
max
n
22