Samsung VRR P10 Produkthandbuch - Seite 6

Blättern Sie online oder laden Sie pdf Produkthandbuch für Monitor Samsung VRR P10 herunter. Samsung VRR P10 50 Seiten.

Temperature and humidity range:
Working temperature and humidity
range
Storage temperature
range
Each main power cable can carry a maximum current of 16A. Note that the total
current of the cabinets cascaded in one main power cable should not exceed
16A. Refer to Table 7-1 for the specific quantity.
Surge protection device of power should be added in the power distributor.
After the display is idle for a period of time, please turn on the power and input the
signal for the first time, and adjust the brightness of the display to the lowest level
for about half an hour and gradually increase the brightness gradually, then use it
normally.
Please provide a good ventilation environment for the display to facilitate the heat
dissipation of the display; and keep away from flammable and explosive
materials.
Since the display LED lamps of the VRR P10 are relatively fragile, do not collide
the surface with hard and sharp objects to prevent damage to the lamp body.
Hot swapping is not allowed. Damage to the connector pins caused by hot
swapping is not covered by the warranty.

2.4 Instructions for Use

Do not place the VRR P10 in an environment where moisture, dust, corrosion,
extreme cold and heat (exceeding the temperature of the parts), as this
environment can cause LED damage or discoloration on the module.
-30 ~ 50 ℃/ 10% ~ 90%
and
humidity
-30 ~ 60 ℃/ 10% ~ 95%
6 / 50