Siemens UP 221 E Technische Informationen zum Produkt - Seite 3

Blättern Sie online oder laden Sie pdf Technische Informationen zum Produkt für Schalter Siemens UP 221 E herunter. Siemens UP 221 E 4 Seiten. Wall switch, single/dual

Siemens UP 221 E Technische Informationen zum Produkt
Wall switch, single UP 221 E
Wall switch, dual UP 222 E
A1 Transparent frame with switch buttons
A2 Transparent plastic labeling film
A3 White label holder
A4 Mounting screws
A5 Switch main module
A6 Design frame (DELTA line/vita/miro)
A7 Wall mounted bus coupling unit UP
A8 Switch button
A9 LED for orientation lighting
A10 PEI interface on wall switch module
A11 PEI interface on bus coupling unit
A12 Status LED
Mounting and wiring
General description
The wall switch UP 221 E / UP222 E is slid onto the bus
coupling unit UP together with its DELTA line / vita / miro
frame. The electric connection between the wall switch
UP 2221 E / UP 222 E and the bus coupling unit UP is
established via a physical external interface (PEI).
Mounting
The bus coupling unit UP (A7) is mounted into
a flush-mount box (see installation instruction of
the bus coupling unit UP).
Remove the transparent frame with the switch
buttons (A1) from the wall switch's main module
(A5) by inserting a screwdriver laterally into the
recesses and lifting the transparent frame up-
wards from the main module.
Slip the wall switch's main module (A5) to-
gether with the design frame DELTA line /
DELTA vita / DELTA miro (A6) onto the bus
coupling unit UP.
Attach the wall switch's main module to the bus
coupling unit UP (A7) with the screws delivered
in the package (A4).
To write a label separate the white label holder
(A3) from the transparent frame. Label a trans-
parent plastic labeling medium (A2) (e.g. Avery
Zweckform No. J4720 for inkjet printers or
Avery Zweckform No. L4770 for laser printers)
that you insert into the transparent frame (A1)
with the tranparent medium (A2) and the white
label holder (A3).
Slide the transparent frame back onto the main
module (A5).
Unmounting
Remove the transparent frame with the switch
buttons (A1) from the wall switch's main module
(A5) by inserting a screwdriver laterally into the
Siemens AG
Bereich Automation and Drives
Geschäftsgebiet Electrical Installation Technology
Postfach 10 09 53, D-93009 Regensburg
recesses and lifting the transparent frame up-
wards from the main module.
Loosen the screws securing the wall switch's
main module to the bus coupling unit UP (A7).
Remove the wall switch's main module (A5) to-
gether with the design frame DELTA line /
DELTA vita / DELTA miro (A6) from the bus
coupling unit UP (A7).
Dimension Diagram
Dimensions in mm
55
55
General Notes
• Any faulty device should be returned to the local
Siemens office.
• If you have further questions concerning the product
please contact our technical support.
! +49 (180) 5050-222
! +49 (180) 5050-223
"
http://www.siemens.com/automation/support-request
UP 22x E, 4 Seiten
© Siemens AG 2005
Änderungen vorbehalten
instabus EIB
Technical Product Information
June 2005
5WG1 221-2EB..
5WG1 222-2EB..
Technik-Handbuch
Update: http://www.siemens.de/gamma
2.16.1.9/3