Cleaning filters
After each wash check the filters for
1.
residue.
Turn the coarse
2.
2
filter anticlock-
wise
and re-
move the filter
system
⁠ .
1
Pull down the mi-
3.
cro filter to re-
move.
Troubleshooting
Fault
Cause and troubleshooting
E:32-00 will light up al-
Supply hose is kinked.
ternately or indicator for
Install the supply hose without kinks.
water supply lights up.
Water tap is turned off.
Turn on the water tap.
Water tap is jammed or furred up.
Turn on the water tap.
The flow rate must be at least 10 l/min when the water sup-
ply is open.
The filters in the water connection of the supply or AquaStop
hose are blocked.
Switch off the appliance.
1.
2.
Pull out the mains plug.
3.
Turn off the water tap.
4.
Unscrew the water connection.
5.
Remove the filter from the sup-
ply hose
6.
Clean the filter.
7.
Re-insert the filter in the supply hose.
8.
Screw the water connection back on.
Check the water connection for leaks.
9.
Restore the power supply.
10.
Switch the appliance on.
11.
Press the locking
4.
2
catches
to-
gether and lift
1
the coarse filter
out
⁠ .
Clean the filter elements under running
5.
water.
Re-assemble the filter system.
6.
Insert the filter system into the appliance
7.
and turn the coarse filter clockwise.
Make sure that the arrow markings
match up.
Fault
E:92-40 will light up al-
ternately.
E:61-02 will light up al-
ternately.
Remnants of food on
tableware.
All manuals and user guides at all-guidesbox.com
Cleaning spray arms
Unscrew the upper spray arm
and
1.
pull down to remove
⁠ .
Pull up the lower spray arm to remove.
2.
Check the outlet nozzles on the spray arms for blockages un-
3.
der running water and remove any foreign bodies.
Insert the lower spray arm.
4.
a The spray arm clicks into position.
5.
Insert the upper spray arm and screw it firmly in place.
Cause and troubleshooting
Filters are soiled or blocked.
Clean the filters.
Wastewater pump is blocked.
Clean the wastewater pump.
Cover of the wastewater pump is loose
Secure the cover of the Wastewater pump so it clicks into
position.
Tableware is placed too close together or basket is overfilled.
1.
Arrange tableware with sufficient space in between.
The spray jets must reach the surfaces of the tableware.
2.
Avoid points of contact.
Spray arm rotation is blocked.
Arrange tableware so that it does not obstruct spray arm ro-
tation.
Spray arm nozzles are blocked.
Clean the Spray arms.
Filters are soiled.
Clean the filters.
Filters are inserted incorrectly and/or not engaged.
1.
Insert the filters properly.
2.
Engage the filters.
Washing programme selected too weak.
Select a more intensive washing programme.
Clean wastewater pump
Disconnect the appliance from the power supply.
1.
Remove the filter system.
2.
3.
Scoop out any water.
1
Prise off the pump cover using a
4.
spoon and grip it by the crosspiece.
2
Lift the pump cover inwards at an angle and remove.
5.
Remove any remnants of food and foreign bodies in the area
6.
of the impeller.
Insert the pump cover
7.
down
⁠ .
a The pump cover clicks into position.
Install the filter system.
8.
Fault
Cause and troubleshooting
Removable streaks are
Amount of rinse aid to be dispensed is set too high.
present on glasses, glass-
Set the rinse aid system to a lower setting.
ware with a metallic ap-
No rinse aid has been added.
pearance and cutlery.
Add rinse aid.
Rust spots on cutlery.
Cutlery is not sufficiently rust-resistant. Knife blades are often
more severely affected.
Use rust-resistant tableware.
Cutlery may also rust if washed together with rusting items.
Do not wash rusting items.
Detergent residue is
Spray arms were blocked by tableware so detergent was not
present in the detergent
rinsed out.
dispenser or the tablet
Check that the spray arms are not blocked and can rotate
collecting tray.
freely.
and press
2