3Com SuperStack II 3C16665A Benutzerhandbuch - Seite 4
Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Schalter 3Com SuperStack II 3C16665A herunter. 3Com SuperStack II 3C16665A 9 Seiten. Hub 6 port fiber
Front Panel
1
6 Optical Fiber Ports
To connect the unit to a fiber optic network you will need optical fiber
cables terminated with ST bayonet type connectors. Take care to keep
the ends of the cables clean. Wipe with a tissue moistened with ethanol
if necessary.
Connect one of the cables to the Rx connector and the other to the Tx
connector of one port on the unit. To tighten the connectors, align the
keyways with the bayonets, push and twist until locked. The other end
of the cables should connect to the opposite ports (Rx to Tx and Tx to
Rx) of a compatible IEEE 802.3 10BaseFL device.
Optical Safety
Under normal viewing conditions there is no eye hazard from
the transmit LED. It is recommended, however, that the LED is
not viewed through any magnifying device whilst it is powered
on. It is advisable that the fiber Tx port and fiber cable ends are
never viewed directly when powered on.
Sécurité optique
Dans les conditions normales de vision, la diode transmission
ne présente pas de risques pour les yeux . Il est toutefois
recommendé de ne pas regarder à travers un dispositif
amplificateur la diode quand elle est sous tension. Il est
conseillé de ne pas regarder directement le port Tx fibre optique
et le cable fibre optique quand ils sont sous tension.
Optische Sicherheit
Unter normalen Umständen geht von der übertragenden LED
keine Gefahr für die Augen aus. Es wird aber empfohlen, die LED
nicht durch Vergrößerungslinsen zu betrachten solange die
Leuchtdiode unter Strom steht. Ebenso ist es ratsam den
Glasfaser Tx Anschluß und die Enden der Glasfaserkabel nicht
direkt zu betrachten solange diese unter Strom stehen.
2
STATUS LEDs
The STATUS LEDs show the partition state of a port and whether or not
the Optical Idle signal is present on the segment connected to a port.
Top Row of LEDs
Green on
The Optical Idle signal is being received and the segment
attached to the port is functional. If the port does not
transmit/receive, check the Disable On Boot switch, 14 , is
Enabled.
Green off
The Optical Idle signal is not being received.
Make sure the transceiver attached to the DTE is cor-
rectly connected and powered up.
Check that the attached DTE is switched on.
Check that the attached transceiver is not faulty.
Carry out the checks recommended for when a STATUS
LED is red.
Check for no more than 4 repeater stacks in series, and
that cable lengths do not exceed the maximum speci-
fied in the standard for that medium.
Bottom Row of LEDs
Red on
The port is partitioned from the network.
Check the connections and the cable for any breaks in the
segment.
If the cause of the partition is found and corrected, the
segment is reconnected automatically, after the first valid
packet is transmitted to, or received from the segment.
Red off
The port is not partitioned.
If these checks do not identify the cause of a problem, it may be that the
Hub 10 6 Port Fiber or the device connected to the port is faulty.
Contact your supplier for further advice.
3
TCVR LED
The TCVR LED lights red if the Transceiver Module port has partitioned.
Refer to section STATUS LEDs for information on what to do if a segment
is partitioned.
A transceiver module port connected to coaxial cable segment
i i i
may partition if the segment is incorrectly terminated.
The Transceiver Module port may partition if the SQE test pulse is
enabled on its transceiver. SQE test should be disabled on transceivers
used to connect 802.3 repeaters to the network.
4
AUI LED
The AUI LED lights red if the AUI port has partitioned. Refer to
LEDs "
, 2 , for information on what to do if a segment is partitioned.
An AUI port connected to coaxial cable segment may partition
i
if the segment is incorrectly terminated.
The AUI port may partition if the SQE test pulse is enabled on its
transceiver. SQE test should be disabled on transceivers used to connect
802.3 repeaters to the network.
5
UNIT LEDs
The UNIT LEDs indicate the position of this unit in the stack, providing a
Management Module or Advanced RMON Module has been fitted to a
unit in the stack. The appropriate UNIT LED will light green; if this unit
has a Management Module (or Advanced RMON Module) fitted, it will
show as unit number 1. If the unit is in a stack which does not contain a
Management Module or Advanced RMON Module, the UNIT LEDs will
not light.
6
Packet LED
The Packet LED flashes yellow whenever a packet is received on one of
the 6 fiber ports, the AUI port, or the Transceiver Module port.
If this LED does not flash, there are no packets being received by the
unit.
7
Collision LED
The Collision LED flashes yellow when a packet collision has been
detected on a segment connected to one of the 6 fiber ports, the AUI
port, or the Transceiver Module port.
Under normal 802.3 operation, collisions occur and cause the Collision
LED to flash. The probability of collisions increases during heavy activity
on the network. The Auto Partition/Reconnection function partitions a
segment from the rest of the network if more than 64 consecutive
collisions are detected on that segment.
8
Power LED
The Power LED lights green to indicate the power supply to the unit is
correct. If it is not lit, and:
None of the ports work
Check the fuse in the IEC socket and the
fuse within the power cable's plug (if fitted).
The AUI and Transceiver
The internal fixed fuse for the power supply
Module ports do not work,
to the AUI and Transceiver Module ports has
but the twisted pair ports
blown. Contact your supplier.
work
All ports function normally The LED has failed. Contact your supplier.
9
MGMT LED
The MGMT LED indicates the status of the Management Module or
Advanced RMON Module if fitted.
.
Off
There is no Management Module or Advanced RMON
Module fitted to the Hub 10 6 Port Fiber or the
internal connection to it has been broken.
Green/(Yellow) The Management Module (or Advanced RMON
Module) is fitted and functioning normally.
Green flashing
Management agent software is being downloaded.
Red
There is a fault on the Management Module (or
Advanced RMON Module) or one of the units in the
stack. Check all connections and refer to the
Management Module guide for more information.
" STATUS