About the LED Indicators

The LED indicators change according to the status of the commander and the receiver.
Lit
Flashing
Off
indicator status during normal operation
Standing by
Orange
Warm-up in progress
Green
Projection in progress
Green
Indicator status during an error/warning
Red
Internal Error
Red
Red
Red
Fan Error
Sensor Error
Red
High Temp Error
Wait for about five
Red
minutes, and then
disconnect the power
Red
cable from the electrical
outlet.
Red
High Temp Warning
Orange
Press
to start projection.
is unavailable for about 30 seconds.
The projector is operating normally.
Disconnect the power cable from the electrical
outlet, and contact your local dealer of the
nearest address provided in the Epson Projector
Contact List.
Check the following two points.
• If the projectors are installed next to a wall,
move it away from the wall.
• Clean or replace the air filter.
Lamp Error
Red
Lamp Failure
Red
Replace Lamp
Orange
Red
Auto Iris Error
Red
Power Err.
Red
If the error continues to occur after checking the points above, disconnect the power cable from
the electrical outlet, and contact your local dealer or the nearest address provided in the Epson
Projector Contact List on the Document CD-ROM.
Check the following three points.
• Remove the lamp and check that it is not
cracked. If it is not cracked, reinstall the lamp
and turn on the projector. If it is cracked,
contact your local dealer or the nearest address
provided in the Epson Projector Contact List.
• Check that the lamp and the lamp cover are
securely installed.
• Clean the air filter.
Replace it with a new lamp as soon as possible.
The lamp may explode if you continue to use it in
this status.
Disconnect the power cable from the electrical
outlet, and request maintenance.