Ricoh Pro L5160e Einstellungen Handbuch - Seite 25

Blättern Sie online oder laden Sie pdf Einstellungen Handbuch für Drucker Ricoh Pro L5160e herunter. Ricoh Pro L5160e 44 Seiten. Additional function 2
Auch für Ricoh Pro L5160e: Handbuch (12 seiten)

Ricoh Pro L5160e Einstellungen Handbuch
Items
Pre-Heater
Print-Heater
Post-Heater
Cure-Heater
Drying time per scan
Selectable values
On/Off
20–70°C (68–158°F)
On/Off
20–70°C (68–158°F)
On/Off
20–95°C (68–203°F)
On/Off
20-95°C (68–203°F)
0.0–9.9 seconds (in units of
0.1 seconds)
Changing Printer Settings
Description
Specify the heater settings.
Specify these settings according to
the type and properties of the media
being used.
After decreasing the heater
temperature to secure sufficient
drying time, change the printer
settings as follows:
• Increase the value in "Drying
Time".
• Set "Printing Direction" to
"Unidirectional".
• Select MIM (profile) with a
higher resolution (more
passes).
Depending on the operating
environment, increasing the heater
temperature may cause the
machine's interior temperature to
exceed the permitted range. Be
careful not to increase the heater
temperature too much.
Specify the ink drying time for each
scan.
If blurring occurs at the boundary
between different colors, it may be
reduced by increasing the ink drying
time. However, if you increase it too
much, lines may become thicker or
the nozzle may clog due to dry
nozzles.
23