Removing and Replacing Field-Replaceable Units
Simultaneously pivot both ejector levers toward each other (until they are parallel
Step 9
to the faceplate) to firmly seat the card in the midplane.
The line card cycles through its power-on self-test. The Fail LED stays on briefly
(about 5 to 6 seconds) and then shuts off. If the Fail LED remains on or flashes,
refer to the Cisco 10000 Series Troubleshooting Guide.
Secure the line card in the chassis by tightening the left and right captive screws.
Step 10
To ensure that there is adequate space for additional line cards, always tighten the
Caution
captive screws on each newly installed line card before you insert any additional
line cards. These screws prevent accidental removal and provide proper grounding
for electromagnetic interference (EMI) shielding.
Reconnect any interface cables to the line card if necessary.
Step 11
Configure the line card if necessary. (See the Cisco 10000 Series ESR Software
Step 12
Configuration Guide for information about configuring the line card.)
Note
Cisco 10005 ESR Hardware Overview and Maintenance Guide
3-24
It is not necessary to configure the line card if this is a replacement
installation. The system automatically downloads the necessary
configuration information from the PRE.