FREQUENTLY ASKED QUESTIONS
Q. I cannot adjust my set point on my Zone Controller any more than 2
lower than the Master Controller.
O
A. 2
is the default setting for master temperature offset. ActronAir recommend this 2
offset to optimise temperature control and maximize energy effi ciency. Moving this
O
setting +/- 2
will result in temperature inaccuracy. Contact ActronAir technical support:
Q. Cooling and Heating seems to take a long time to achieve temperature in ESP
fan mode. Am I using the correct settings?
A. ESP fan mode really comes into it's own when minimal zones are used. For quicker
and more responsive Cooling and Heating, when using more than minimal zones,
select HIGH or CONT HIGH fan speed on Master Controller. This will boost heating
and cooling and is best optimized when you want to condition more than the minimal
zone set up.
Q. Cooling and Heating is not suffi cient in my zone.
A. Air balancing is essential part of system commissioning in ESP Ultima system. The
duct design may be prohibiting the correct amount of airfl ow reaching your area.
Please contact your installer to ensure air balancing has been carried out.
Q. There is substantial air noise coming from my outlet.
A. If the outlet gets too noisy when the unit or zone is fi rst turned on, the system maybe
over supplying airfl ow to your area. Ensure ESP fan mode is selected when minimal
zones are used.
Q. There are dashes across my control display.
A. Make sure you have not had a power interruption. If this is still present on the display
after 20 seconds, please contact your installer. Incorrect wiring or a broken circuit
could also cause these symptoms.
FAULT CODES:
When E? is displayed in the Master Controller or Zone Controller, take note of the
digits after E and contact your installer.
E3 - System has detected less than 2 sensors (Ultima requires at least 2 sensors
in circuit) or, a remote sensor is short circuit.
E5 - No Communication. The system is constantly relaying information back and forth.
This indicates the communication is not happening. Contact your installer to check
your wiring and cable's integrity.