3
Loading Material

3.2 Adjusting the Present Sensor

HS / HS+
1
2
3
Fig. 7
Adjusting the present sensor
Reaching the peel position will be recognized by displacement of the feeler (1)
by the label to be peeled-off.
1. Release the present sensor (2) by turning the knob (3) counterclockwise.
2. Move the present sensor (2) sideward to adapt the sensor position to width
and shape of the labels.
3. Swing the present sensor (2) to adjust the distance between feeler (1) and
dispense plate (4).
4. Hold the sensor (2) firmly in the needed position and fix it by turning the
knob (3) clockwise.
Fig. 8
Sensor settings
2
4
1
4
VS / VS+
11
3