5
External Start-Sensor
14
5.1
Connection
The start signal to apply the label can originate from an external sensor connected to the 3 pole connector (1)
connected directly to the applicator.
Fig. 10
Start signal connector on the applicator
Fig. 11
Examples of connections of start sensors
The start of the printing job - print first label is still initiated over the I/O interface of the printer. Circuitry and
programming of the connections is to be set as illustrated.
5.2
Signals
•
The signal FSTLBL respectively DREE
waiting position.
•
The signal START will transport and apply the label to the product.
In the application mode "Apply - Print" the printing of the next label starts directly after application of the previous label.
In the application mode "Print - Apply" the signal START must be sent for the print.
Pin
Signal Name
1
FSTLBL
DREE
13
START
Interface description of the printer
Table3
without applicator
-
(Hermes+)
Print start signal
Precondition: The superior control
has confirmed with the ETE signal
that the previous label has been
taken from the peel-off position.
A section of the interface description of the label printer
1
causes the label to be printed which is then transported to the
(Hermes+)
Description
with applicator
Cycle sequence = Apply-Print
Print first label
Start of printing and
labeling
Activation/active status
Switch on +24V between
Pin 1 and Pin 25
+24V between Pin 13 and Pin
25