Installing the Router Card
X.21 Connections
The X.21 connector uses a 15-pin connector for balanced circuits and is commonly used in the
United Kingdom to connect to the public data network. X.21 relocates some of the logic functions
to the DTE and DCE interfaces and, as a result, requires fewer circuits and a smaller connector than
EIA/TIA-232.
The network end of the X.21 serial transition cable (not included) is a standard DB-15 connector, as
shown in Figure 6. The end that connects to the serial port on the router card has a DB-60 connector.
X.21 cables are available with a plug or receptacle in either DTE or DCE mode. To order a cable,
refer to the section "Obtaining Service and Support" at the end of this document.
Figure 6
EIA-530 Connections
The EIA-530 standard, which supports balanced transmission, provides the increased functionality,
speed, and distance of EIA/TIA-449 on the smaller, DB-25 connector used for EIA/TIA-232, instead
of the 37-pin connector used for EIA/TIA-449. Like EIA/TIA-449, EIA-530 refers to the electrical
specifications of EIA/TIA-422 and EIA/TIA-423. Although the specification recommends a
maximum speed of 2 Mbps, EIA-530 is used successfully at 4 Mbps or faster speeds over short
distances.
The EIA-530 serial transition cable (not included) is available in DTE mode only. The network end
of the EIA-530 adapter cable is a standard DB-25 plug commonly used for EIA/TIA-232
connections, as shown in Figure 7. The end that connects to the serial port on the router card has a
DB-60 connector. To order a cable, refer to the section "Obtaining Service and Support" at the end
of this document.
Figure 7
Installing the Router Card
This section guides you through the installation of the router card and includes the following
subsections:
•
•
•
10 Router Card (WS-X3011) Configuration Note
X.21 Serial Transition Cable Connectors, Network End
1
8
9
15
EIA-530 Serial Transition Cable Connector, Network End
Required Tools and Equipment
Connecting the Console Terminal
Connecting to a Network
DTE
DCE
DTE