Cisco 1005-CH - 1005 Router - EN Handbuch für den Einsatz - Seite 37

Blättern Sie online oder laden Sie pdf Handbuch für den Einsatz für Drahtloser Zugangspunkt Cisco 1005-CH - 1005 Router - EN herunter. Cisco 1005-CH - 1005 Router - EN 40 Seiten. Lightweight access points

Cisco 1005-CH - 1005 Router - EN Handbuch für den Einsatz
Deployment

Cisco 1000 Series Lightweight Access Point Placement

Example
The Cisco 1000 series lightweight access point coverage areas should overlap approximately 10% to
Note
15% to minimize the number of coverage holes.
The large "X" in the middle of each circular Cisco 1000 series lightweight access point coverage
Note
area--those are the indicated locations of the associated Cisco 1000 series lightweight access points.
78-17279-01
Place Cisco 1000 series lightweight access points on the floor plan using the
Constraints" and
"Access Point Placement
touching or slightly overlapping as illustrated in the following example.
The open auditorium (a Warehouse/Manufacturing Building Type) shown in the
or Building Floor
Plans" section is approximately 20,000 square feet.
As described in the
"Voice over IP
requires approximately 6 Mbps 802.11b throughput, resulting in a minimum A = 5,000 square foot
coverage area per Cisco 1000 series lightweight access point for an open area.
Dividing 20,000 square feet by A = 5,000 square feet per Cisco 1000 series lightweight access point
results in at least four Cisco 1000 series lightweight access points required for the auditorium.
According to the guidelines in
coverage area results in an R = 50-foot coverage circle radius, or Z = 71-foot coverage square.
On your floor plan map, arrange four 50-foot radius coverage circles so they overlap, as shown in
the following figure.
Cisco 1000 Series Lightweight Access Point Placement Guidelines
Guidelines" sections such that coverage circles are
Requirements" section, a typical SpectraLink NetLink Telephone
"Determining Deployment
Deployment Guide: Cisco Aironet 1000 Series Lightweight Access Points
"Noting Deployment
"Collecting Maps
Requirements," an A = 5,000 square foot
19