Air Venturi's
Each air venturi will operate different banks of jets to allow you to customise your whirlpool
experience.
Additional Control Pad, Sanitising system
If you have ordered the optional sanitising system/ bath
product dispenser, you will have an additional control
pad and a chrome filling closure included beside each
other on the top of your Bette whirlpool rim. (Pictured
here) The function on the RHS of this pad is used to
activate the sanitising feature. The function on the LHS
indicates when the dispenser needs refilling and the LED
light will light up. The storage filling closure is top filling
and will hold up to 1.5litres of product.
To operate
Press the RHS button on the control pad and the liquid contained it the dispenser will be
dispersed with the pump running for 30 seconds, and then the pump will shut down. Relative
to cleaning product, Check the manufacture's instructions and warning notes before using
any type of cleaner on your whirlpool. Use only soft cloths, sponges or chamois to clean the
surface, under no circumstances should scrubbing brushes/ sponges, steel wool or any tools
be used.
Do Not Use any scouring or aggressive and or rough cleaning agents. Chorine based
disinfectants and aggressive cleaners (EG acetone, thinners etc) may attack and or bleach the
fittings or enamelled surface. This will disperse approximately 1ml of product to each litre of
water. (This will amount to about 100ml in 30 seconds)
Leave the sanitised water solution in the whirlpool for 30 minutes, then empty and rinse the
whirlpool. You can choose to run the pump for some of this time; however, air venturis should
be in the off position to prevent excessive foaming of the sanitising agent. The sanitising
function has a dry running protection sensor that prevents the system from operating should
there be no product in the reservoir.
7
5 Testing and sheeting
Although the whirlpool was fully tested in the factory prior to dispatch, damage may have
occurred during transport or installation. Therefore the following procedures should be carried
out now;
- Check to make sure the electrician has tested the whirlpool and connected the 3 pin power
plug to the whirlpool system. (This will have been removed after testing by the factory)
- Check that the whirlpool is clean and free of debris.
- Fill the bath with water above the level of the jets.
- Switch on the system (see Operating Instructions Page 5-8)
- Now check all functions are working.
-Check all water seals for possible leaks.
- Allow the whirlpool to run for 10 minutes.
- Check again for leaks, (check pipes, joints, coupling and jets)
Once you have completed these checks, sheeting
with villa board or similar approved wet area product
can be performed. Remember to install and allow for
access panel fittings when sheeting up.
An approved wet seal membrane will need to be applied
after sheeting has occurred and prior to tiling proceeding
in accordance with the approved standard.
Once tiling and grouting have been completed, apply a
bead of approved silicon based sealant to the edges of
he bath where it meets the tiles.
6 Need any Help
Ring Argent Technical advice hotline if required, Toll Free on 1800 356 717
If taking advantage of this service, please have your warranty number detail, which is located
on the control box and will start with the following prefix PMFG, prior to ringing to allow our
team to assist you as efficiently as possible.