To ensure proper performance of the DL-SE3H1V-C, it is recommended that you use solid core
shielded Category 6 F/UTP cabling at a minimum. Category 5e F/UTP may perform well but
may not support power over HDBaseT reliably.
For optimized performance use the following Liberty Wire and Cable branded cabling;
Category 6 plenum; 24-4P-P-L6SH
Category 6A plenum; 24-4P-P-L6ASH
Category 6 NON-plenum; 24-4P-L6SH
Category 6A NON -plenum; 24-4P-L6ASH
Twisted Pair Wiring
Use TIA/EIA-568B wiring for Category 6
connection between send and receive units.
RELAY Wiring for both RELAY Outputs
For the normally open contacts, connect a circuit
between the NO and COM terminals of the 3-pin
For the normally closed contacts, connect a circuit
between the NC and COM terminals of the 3-pin
phoenix connector
RS232 Wiring
Connect the controller or device RX signal to TX port of the DL-SE3H1V-C receiver. Then
connect the controller or device TX signal to the RX port on the DL-SE3H1V-C receiver.
Cabling Requirements
When using shielded category cabling ALWAYS...
....use shielded connectors
....properly ground the category cable
1
8
TIA/EIA-568B
P n 1
P n 2
P n 3
P n 4
P n 5
P n 6
P n 7
P n 8
I/O STATE
ON
OFF
DL-SE3H1V-C
Controller or
RX
Device
Tx
Rx
Or n e/Wh te
Or n e
Green/Wh te
Blue
Blue/Wh te
Green
Brown/Wh te
Brown
RELAY STATE
NO
NC
CLOSED
OPEN
OPEN
CLOSED
RXD
TXD
GND