DigitaLinx DL-1H1V1U-WP-W Benutzerhandbuch - Seite 14

Blättern Sie online oder laden Sie pdf Benutzerhandbuch für Transmitter DigitaLinx DL-1H1V1U-WP-W herunter. DigitaLinx DL-1H1V1U-WP-W 19 Seiten.

DL-1H1V1U-WP-W Owners Manual

RS232 Control and Configuration

An RS232 enabled displays ON and OFF status can be controlled by the DL-1H1V1U-WP-W via RS232 from the
DL-HD2-RX by pressing the DISPLAY button on the DL-1H1V1U-WP-W.
To turn the display ON using RS232, simply quick press the DISPLAY button on the DL-1H1V1U-WP-W; to turn
display OFF simply long press the DISPLAY button on the DL-1H1V1U-WP-W for 3-5 seconds.
RS232 ON command can also be automatically sent to a display when an active video source is connected to
the
DL-1H1V1U-WP-W.
When using auto RS232 on / off control of a display, use the RS232 delay commands to
determine the time when the display will be turned OFF when no video signals are present in the DL-1H1V1U-
WP-W.
For example if the delay time is set to 3 minutes, the RS232 enabled display will turn off when there is no
present video signal in the switcher / extender for 3 minutes. By default the auto RS232 control is on and the
default delay time is set to 5 minutes.
Use the commands below to adjust the settings for RS232 control, be sure to consult the displays owners
manual for the correct RS232 settings and commands so RS232 control can be generated by the DL-HD2-RX
receiver.
Description
Auto RS232 On/Off
Query Auto RS232 Mode Status
Reset Auto RS232 Mode to
Factory Default
(Default is ON)
Set RS232 Power OFF Delay
Time
Query RS232 Power OFF Delay
Time
Reset Auto RS232 Delay Time
to Factory Default
(Default is 5 minutes)
14
Command
SET AUTOUART_M {x}
{x} = [on, off]
GET AUTOUART_M
RESET AUTOUART_M
SET AUTOUART_D {t}
{t} = [1-60]
Note: Maximum delay time is 60
minutes
GET AUTOUART_D
RESET AUTOUART_D
Example
Command: SET AUTOUART_M on<CR><LF>
Return: AUTOUART_M on <CR><LF>
Command: GET AUTOUART_M<CR><LF>
Return: AUTOUART_M on <CR><LF>
Command: RESET AUTOUART_M<CR><LF>
Return: AUTOUART_M on <CR><LF>
Command: SET AUTOUART_D 10<CR><LF>
Return:AUTOUART_D 10 <CR><LF>
Command: GET AUTOUART_D<CR><LF>
Return: AUTOUART_D 10<CR><LF>
Command: RESET AUTOUART_D<CR><LF>
Return: AUTOUART_D 5 <CR><LF>