Argo DADOS XL Betriebsanleitung - Seite 6

Blättern Sie online oder laden Sie pdf Betriebsanleitung für Klimagerät Argo DADOS XL herunter. Argo DADOS XL 11 Seiten. Local air conditioner

Argo DADOS XL Betriebsanleitung
3. HEATING MODE
Press FUNCT to select Heating until the relevant icon appears.
By default, the temperature is set to 25ºC.
The temperature can be adjusted between 15° and 25°C.
In this way, each time the Power button is pressed, the unit switches off, the appliance saves the temperature set
and when switched back on again, it will retain this setting.
In this way, fan speed can be adjusted; the Timer and ECO function can be set.
TO USE THE AIR-CONDITIONER IN HEATING MODE, ROTATE THE PRODUCT 180º AROUND ITSELF AND
CONNECT THE CONNECTOR AND THE FLEXIBLE HOSE AS USUAL; THEN SELECT THE HEATING FUNCTION
ON THE REMOTE CONTROL OR, IF YOU DO NOT HAVE A REMOTE CONTROL, ON THE CONTROL PANEL.
4. FAN MODE
Press FUNCT to select Fan until the relevant icon appears.
When the unit operates in this mode, the display will show FF and the icon
This enables the adjustment of fan speed.
The temperature cannot be regulated.
This equipment automatically vaporises the condensation in Cooling and Heating mode.
Ensure that when the unit operates as Cooling or Heating, the rubber cap that closes the discharge hole at the back is
correctly positioned.
When the air-conditioner operates on Cooling and Heating, there is no need to arrange for continuous drainage of
condensate; only in specific weather conditions where air humidity levels are very high may water deposit within the unit.
When the internal tank is full, the blue LED flashes to warn that it is full and blocks the appliance function.
V 07/13
HOW TO ELIMINATE CONDENSATE
To empty the container, switch the air-conditioner off and unplug. Remove the
rear drainage hole cap and connect a little tube through which to drain the
condensation; place the other end on top of a normal drain.
Ensure that the tube is not twisted or bent. The tube must slope downwards.
Close the drain again with the cap and resume use of the air-conditioner.
ATTENTION!
When using the air-conditioner in Dehumidification mode, we recommend
always ensuring continuous drainage, in order to guarantee maximum
dehumidification efficiency.
lights up.
6