Output signals

4)
VBS/SDI-1/2/3
BNC type (1 each)
VBS, 1.0 Vp-p, 75 ohms
SDI format, 270 Mbps, SMPTE 259M
5)
SDI-4/5/6
BNC type (1 each)
SDI format, 270 Mbps, SMPTE 259M
6)
Y/R-Y/B-Y video
BNC type (1 each)
Y: 1.0 Vp-p, 75 ohms
R-Y/B-Y:
NTSC:
J: without setup, 756 mVp-p, 75 ohms
UC: with setup, 700 mVp-p, 75 ohms
(factory setting)
PAL: 525 mVp-p, 75 ohms
6)
R/G/B video
BNC type (1 each)
700 mVp-p, 75 ohms
PIX
BNC type (1)
1.0 Vp-p, 75 ohms
WF
BNC type (1)
NTSC: 714 mVp-p, 75 ohms
PAL: 700 mVp-p, 75 ohms
Encoded output: 1.0 Vp-p, 75 ohms
WF MODE
4-pin (1)
AUDIO OUTPUT
XLR, 3-pin
0 dBu/–20 dBu, balanced, 2 channels
SYNC
BNC type (1)
0.3 Vp-p, 75 ohms
4)
The signal selection (VBS or SDI) output from the VBS/SDI 1/2/
3 connectors is switchable.
5)
SDI signal is output only when SDI signal output is selected for
the VBS/SDI-1 connector.
6)
R/G/B and Y/R-Y/B-Y are switchable.

Camera input/output signals

CAMERA
Triax (Kings type for the U.S.A. and
Canada, Fischer type for Europe)
COAX
BNC type (1), 75 ohms
REMOTE
8-pin, multiconnector
ETHERNET
IEEE 802.3 10BASE-T, IEEE 802.3u
100BASE-TX
INTERCOM/TALLY/PGM
D-sub, 25-pin (1)
4W/RTS
TALLY: 24 V DC, TTL level or contact
selectable
MIC REMOTE
D-sub, 15-pin (1)
INCOM (on the front panel)
XLR, 5-pin (1)
16
Specifications

Supplied accessories

AC power cord (1)
AC power plug holder (1)
4-pin connector (1)
Number plate (1 set)
Operation Manual (1)
CD-ROM (1)

Optional accessories

Extension board (service parts)
Design and specifications are subject to change without
notice.
Note
Always verify that the unit is operating properly before
use. SONY WILL NOT BE LIABLE FOR DAMAGES
OF ANY KIND INCLUDING, BUT NOT LIMITED
TO, COMPENSATION OR REIMBURSEMENT ON
ACCOUNT OF THE LOSS OF PRESENT OR
PROSPECTIVE PROFITS DUE TO FAILURE OF
THIS UNIT, EITHER DURING THE WARRANTY
PERIOD OR AFTER EXPIRATION OF THE
WARRANTY, OR FOR ANY OTHER REASON
WHATSOEVER.