Argo XFETTO DCI HPL Installationsanleitung Handbuch - Seite 14
Blättern Sie online oder laden Sie pdf Installationsanleitung Handbuch für Klimagerät Argo XFETTO DCI HPL herunter. Argo XFETTO DCI HPL 17 Seiten. Installation instructions for air conditioner
TROUBLESHOOTING
The use of portable telephones near the air conditioner
•
may cause disturbance to its normal operation and must
be avoided. In case abnormal operation is noticed,
(OPERATION lamp lights, but the air conditioner will not
run) to restore normal operation turn-off electric supply for
EG
about 3 minutes, by disconnecting the main switch or the
wall plug, then start again the air conditioner.
If your air conditioner does not work properly, first check
•
the following points before requesting service.
If it still does not work properly, contact your dealer or
service centre.
Trouble: the air conditioner does not run at all.
Possible cause:
1. Power failure.
2. Leakage breaker tripped.
3. Operation button is OFF.
4. Batteries in remote control unit have run down.
Remedy:
1. Restore power.
2. Contact service centre.
3. Press the button again.
4. Replace batteries.
AUTO-DIAGNOSIS
LEDS
STANDBY OPERATION
F
F
O
●
F
F
F
F
O
O = LED OFF
= LED ON
●
F = Flashing LED
WARNING
TIMER
F
O
Defective indoor air sensor
●
F
Defective outdoor air sensor
F
F
Defective indoor air coil sensor
F
F
Defective outdoor air coil sensor
O
O
Defective compressor discharge temperature sensor
●
O
Malfuctioning of electronic PCB (current protection)
●
O
Malfuctioning of electronic PCB (temperature protection)
●
●
Malfuctioning of PFC (power factor correction system)
F
O
Malfunctioning of the condensate drainage system
Trouble: Poor cooling or heating performance.
Possible cause:
1. Dirty or clogged air filters.
2. Heat source or many people in room.
3. Doors and/or windows are open.
4. Obstacle near air intake or air discharge port.
5. The set temperature on the remote control unit is too
high.
6. Outdoor temperature is too low (heat pump version).
Remedy:
1. Clean air filters to improve airflow.
2. Eliminate heat source if possible.
3. Shut them to keep the heat or cold out.
4. Remove it to ensure good airflow.
5. Set the right temperature on the remote control unit.
6. Try to use a back-up heater.
Trouble: Clicking sound is heard from the air conditioner.
Possible cause:
1. During operation, any plastic parts may expand or shrink
due to a sudden temperature change. In this event, a
clicking sound may occur.
Remedy:
1. This is normal, and the sound will disappear when an
even temperature is settled.
Trouble: The electrical heating does not run.
Possible cause:
1. The required temperature is too low.
2. The electrical heater has not been activated.
Remedy:
1. Set an higher temperature on the remote control.
2. Activate the electrical heater pressing the FILTER button
of the remote control (only during HEATING and FAN
mode).
POSSIBLE CAUSE
13