2-1-5. IMAGER SECTION

ns: not supplied
Anti Shake Unit Section
(See page 2-8)
202
Note 2: Refer to "3-2. CLEANING PROCEDURE OF OLPF" on
page 3-2 for method of cleaning the OLPF.
Note 3: Precautions for Replacement of Imager
• If the imager has been replaced, carry out all the adjust-
ments for the camera section.
• As the imager may be damaged by static electricity from
its structure, handle it carefully like for the MOS IC.
In addition, ensure that the receiver is not covered with
dusts nor exposed to strong light.
Ref. No.
Part No.
Description
201
A-1935-767-A
IM IMAGER UNIT ASSY (876)
(including CP6001 (CMOS imager) and IS-1007
complete board) (Note 1, 2, 3)
202
4-194-226-01
IM PLATE, LPF RETAINER
203
1-856-482-11
FILTER BLOCK, OPTICAL (Note 1, 2)
204
4-281-915-01
IM GS TAPE (Note 1)
205
4-281-914-01
IM SPACER (869) (Note 1)
SLT-A58K/A58M/A58Y_L2
201
(including CP6001 (CMOS imager) and IS-1007 complete board)
(Note 1, 2, 3)
203
(Note 1, 2)
204
(Note 1)
205
(Note 1)
204
(Note 1)
ns
#64
209
208
Ref. No.
Part No.
Description
206
4-194-225-01
IM TAPE FPC GUIDE
* 207
4-194-227-01
IM PLATE GUIDE IMAGER FPC
208
1-888-338-11
ISP-2001 FLEXIBLE BOARD
209
1-883-908-11
ISL-006 FLEXIBLE BOARD
#64
2-666-551-21
SCREW, TAPPING, P2
Screw
#64: M1.7 X 5.0 (Tapping)
(Silver)
2-666-551-21
1.7
5.0
Note
Note 1: Refer to the following statements when replacing the Optical
filter block.
Method of Removal
(1) Pour resolvent (alcohol or cleaning agent) between the
imager and the IM spacer.
Wait for that the adhesive power of the IM GS tape
weakens.
(2) Remove the IM spacer from the imager.
Pour resolvent (alcohol or cleaning agent)
between the imager and the IM spacer.
Method of Attachment
(1) Attach the IM GS tape and the Optical filter block by
aligning them with the outer shape of the IM GS tape
evenly.
The two-layer side of the Optical filter block is on the
206
imager side.
(2) Attach the IM spacer fixed tape by aligning it with the
207
outer shape of the IM GS tape evenly.
Peel off the
released paper.
Peel off the
released paper.
#64
The two-layer
side is on the
imager side.
Mount
Imager
Side
Side
Optical Filter Block
(3) Set the Optical filter block in its attachment jig
(J-6082-737-A), with the attached IM GS tape facing
upward.
(4) Press the imager down into the jig as shown below to
attach it to the Optical filter block.
Imager
J-6082-737-A
2-7
Peel off the
released paper.
IM GS Tape
IM Spacer (869)
IM GS Tape
Peel off the released paper.