ACU-RITE MILLPWR G2 Software-Aktualisierung - Seite 6
Blättern Sie online oder laden Sie pdf Software-Aktualisierung für Musik Mixer ACU-RITE MILLPWR G2 herunter. ACU-RITE MILLPWR G2 6 Seiten.
Auch für ACU-RITE MILLPWR G2: Software-Aktualisierung (6 seiten), Software-Aktualisierung (6 seiten), Software-Aktualisierung (6 seiten)
The max feedrate override setting in Job Setup now correctly enforces the acceptable range of
150% to 200%.
The programmed tool field in step forms and on the status bar shows the correct programmed
tool for a tool that is programmed in custom pocket sub-cycles.
Corrected an issue which enabled the user to move the cursor in the active program step listing
while the program is running.
Improved block-form calculation for G-code programs.
The tool now arcs off of the Radial Slot's outer pass when there is no side finish specified.
If not set to "Require Change", a tool change prompt is suppressed unless the programmed tool
does not match the current tool.
When starting a program, the tool path (and tool) graphical display was delayed if the program
had previously been stopped at the tool prompt.
Corrected an issue in which the file system partition settings for a max scheduled disk check
interval were lower than the actual interval at which the check would occur. This could prevent
the ability to create a clone image of the system using the new HC Clone Drive. To ensure
proper settings and checking, a disk check is now forced after every software update.
When starting a program from a step that does not have a programmed tool step associated
with it: 1. The active tool is the last tool mounted. 2. Spindle settings remain OFF.
Improved operational and program management functionality.
Improved spindle direction and speed performance In G-code programs when speed and
direction are within the same block.
If any issues are encountered, please contact your service representative for assistance or
contact technical support at